Sale!

YOKOGAWA ASI133-H00SA3S0 Analog Input Module

The Yokogawa ASI133-H00SA3S0 operates as an intrinsically safe analog input module in the field I/O tier of Yokogawa’s CENTUM VP distributed control systems, digitizing 4-20 mA signals from hazardous-area transmitters into process variables for control logic or safety PLCs. It occupies a single slot in an ESB node carrier like ANB11S, where each of its eight channels incorporates built-in barriers compliant with [Ex]i standards, providing galvanic isolation and energy limiting to safeguard against faults while allowing HART communication passthrough for device configuration over the same loop.

Description

In process control systems where field signals from hazardous areas must traverse into safe zones without compromising integrity or inviting sparks, the Yokogawa ASI133-H00SA3S0 emerges as a vital safeguard for engineers navigating the tightrope of intrinsic safety in volatile environments. Imagine a flare stack in an upstream oil field where unconditioned 4-20 mA inputs from gas detectors trigger false alarms or shutdowns due to induced noise, or a solvent recovery unit where barrier failures expose cabling to explosive vapors, escalating risks and compliance headaches—these perils often arise from modules that skimp on galvanic isolation or fail to enforce energy limits under fault conditions. This analog input module with built-in barriers addresses them by channeling eight isolated channels of current signals directly into your DCS, enforcing IEC 60079-11 intrinsic safety parameters to cap open-circuit voltage at 10 V and short-circuit current at 20 mA, ensuring safe transmission from Zone 1/2 devices while preserving signal fidelity for accurate alarming or trending.

It becomes non-negotiable in industrial automation sectors like petrochemical handling or gas processing, where high reliability in hazardous I/O signal acquisition upholds ATEX/IECEx certifications and minimizes hot work permits. The Yokogawa ASI133-H00SA3S0 mounts into ESB bus nodes like ANB11S, blending seamlessly with CENTUM VP architectures to support HART overlays for remote diagnostics without additional isolators, so you bypass the clutter of external zener barriers. For teams retrofitting legacy safe-barrier setups, it consolidates wiring by integrating protection per channel, reducing installation footprint while enhancing noise rejection up to 1500 V. In expansive process control networks, its extended -20 to +70°C envelope and ISA G3 hardening shrug off vibrations or EMI transients, enabling longer field runs without repeaters. By prioritizing intrinsic safety and modular integration, the Yokogawa ASI133-H00SA3S0 fortifies system stability, empowering precise monitoring in explosive atmospheres that scales with safety interlocks and reduces the engineering toll of fragmented I/O strategies in high-hazard industrial automation landscapes.

When scoping barrier-protected inputs for certified architectures, the Yokogawa ASI133-H00SA3S0 commands evaluation for its channel-efficient design, delivering the signal reliability that insulates processes from ignition threats without diluting data quality.

The Yokogawa ASI133-H00SA3S0 operates as an intrinsically safe analog input module in the field I/O tier of Yokogawa’s CENTUM VP distributed control systems, digitizing 4-20 mA signals from hazardous-area transmitters into process variables for control logic or safety PLCs. It occupies a single slot in an ESB node carrier like ANB11S, where each of its eight channels incorporates built-in barriers compliant with [Ex]i standards, providing galvanic isolation and energy limiting to safeguard against faults while allowing HART communication passthrough for device configuration over the same loop. This setup buffers inputs against common-mode voltages up to 250 V, converting signals via 16-bit ADCs for 0.1% accuracy, with configurable scaling and filtering to match field dynamics.

ASI133-H00SA3S0
ASI133-H00SA3S0

In a layered configuration, it draws 24 V DC from the node while relaying digitized data via the ESB bus to upstream processors, supporting dual-redundant wiring for automatic failover in under 50 ms to maintain scan continuity. It interfaces with barrier-protected field devices like pressure or level transmitters, adhering to FOUNDATION Fieldbus for hybrid extensions, and onboard diagnostics detect wire breaks or overrange conditions, routing alerts to HIS consoles for isolated responses. Positioned at the hazardous/non-hazardous boundary in marshalling cabinets, the Yokogawa ASI133-H00SA3S0 streamlines I/O architecture by eliminating standalone barriers, where its screw terminals facilitate screened cabling in explosion-proof enclosures—cultivating a secure pathway that integrates with SIS via Profisafe, ensuring fault-tolerant data flow across certified zones without compromising update rates or protocol fidelity.

Specification Details
Model Number ASI133-H00SA3S0
Brand Yokogawa
Type Analog Input Module (8-ch, 4-20 mA, Isolated w/ Barriers)
Input Voltage 24 V DC (node-supplied)
Operating Temp Range -20°C to +70°C
Mounting Style Backplane Slot (ESB Node)
Dimensions 35 x 140 x 120 mm (W x H x D)
Weight 0.3 kg
Interface/Bus ESB Bus, HART
Compliance CE, IEC 60079-11 [Ex]i, ISA G3, ATEX
Supported Protocols HART, FOUNDATION Fieldbus
Typical Power Draw 7 W (full load)

Opting for the Yokogawa ASI133-H00SA3S0 instills inputs fortified for unerring precision in volatile zones, clamping signals to intrinsic limits that avert arc energies below 1.3 mJ, dodging the false trips that plague under-barriered loops and enabling tighter setpoint guards without safety overrides, which refines process yields and trims flare gas losses in flare management. This protection extends to HART-enabled diagnostics, surfacing transmitter faults remotely to preempt excursions, often extending mean time between inspections in remote wells.

Barrier integration sharpens maintenance edges too, with per-channel status relays that localize issues for hot-swappable fixes, confining downtime to minutes in zoned setups versus hours for distributed isolators. The module’s node-slot efficiency curtails deployment loads as well—pairing with existing ESB carriers skips barrier panel builds, reallocating engineering from zoning calcs to loop optimization. Crafted for zone resilience, it weathers 10 g shocks and corrosive drafts, with sealed barriers that self-limit faults to uphold long-term performance, ensuring your DCS frontier remains ignition-proof through capacity ramps or hazard reclassifications.

In offshore gas platforms, the Yokogawa ASI133-H00SA3S0 captures separator pressures from [Ex]i transmitters, where its barriers endure salt spray and seismic jolts to secure critical system uptime, locking in flow assurance amid explosive hydrocarbon envelopes.

Refinery alkylation units rely on it for acid concentration monitoring, channeling isolated inputs through HART for real-time adjustments in acid-wet, Zone 1 confines, amplifying high-reliability operations.

For mining ventilation controls in methane-prone shafts, this module aggregates airflow signals, meeting underground certification needs with vibration-proof channels that sustain continuous data cycles for safety ventilation in modular, expandable I/O vaults.

ASI133-S00 – Non-barrier standard variant for safe-area analog acquisition without intrinsic protection.

ASI533-H00 – 16-channel counterpart for higher-density inputs in barrier-equipped nodes.

AST143-S00 – Temperature input alternative with RTD/TC support for thermal barrier apps.

ASR133-H00 – Relay output module for safe actuation from hazardous triggers.

ASD143-S00 – Digital input edition with barrier for binary signals in zoned fields.

ASI133-H00/S1 – Extended diagnostics model with enhanced fault logging for predictive upkeep.

ANB11S – Compatible ESB carrier for housing the ASI133 in hazardous node assemblies.

As you stage the Yokogawa ASI133-H00SA3S0 for your enclosure, validate node firmware against version 5.x for HART barrier passthrough, and torque terminals to 0.6 Nm to seal against gas ingress—overtightening can stress barrier traces. Limit loop loads to 600 ohms max per channel to enforce voltage compliance, and braid shield grounds at the module end only to drain EMI without loops, crucial in bundled runs near solenoids.

Field endurance demands quarterly barrier integrity probes with a megohmmeter at 500 V DC, targeting >10 MΩ isolation in humid zones, paired with a non-sparking brush for dust from vents. Scan channel diagnostics monthly via the FCS pane to log overrange spikes, correlating to field calibrations for drift hunts under 0.2%. Biannual spark tests per IEC 60079-11 confirm energy caps, and tagging serials for rotation aligns with zone audits. This vigilant protocol dovetails with your HAZOP cycles, staving off compromises that erode safety margins.