Sale!

YOKOGAWA ADV551-P50 Safety Digital Input Module

The YOKOGAWA ADV551-P50 integrates seamlessly into Yokogawa’s ProSafe-RS platform as part of a fault-tolerant safety loop. Each module processes 16 digital inputs (24V DC) with dual-channel redundancy, comparing signals internally to detect discrepancies that might indicate a fault. It connects via Yokogawa’s proprietary safety network to ProSafe-RS controllers, using certified safety protocols to ensure deterministic response times – critical for meeting safety system performance requirements (PFD calculations).

Model Number ADV551-P50
Brand Yokogawa
Type Safety Digital Input Module
Input Type 24V DC (Sink/Source)
Channels 16 (Dual-channel redundant)
Safety Certification SIL3 (IEC 61508), TÜV Rheinland
Response Time < 50 ms (configurable)
Operating Temp Range -20°C to +60°C
Mounting ProSafe-RS I/O Unit
Diagnostics Channel faults, wire breaks, short circuits
Power Consumption 2.5 W (typical)
Compliance CE, ATEX, IECEx

Description

The YOKOGAWA ADV551-P50 integrates seamlessly into Yokogawa’s ProSafe-RS platform as part of a fault-tolerant safety loop. Each module processes 16 digital inputs (24V DC) with dual-channel redundancy, comparing signals internally to detect discrepancies that might indicate a fault. It connects via Yokogawa’s proprietary safety network to ProSafe-RS controllers, using certified safety protocols to ensure deterministic response times – critical for meeting safety system performance requirements (PFD calculations).

ADV551-P50

ADV551-P50

The module’s continuous self-diagnostics monitor for issues like field wire breaks, short circuits, or internal component failures, immediately alerting the system to maintain safety integrity. For maintenance, its hot-swappable design allows replacement without taking the entire safety system offline, while the front-facing LEDs provide instant visual status of each channel.

ADV551-P50

ADV551-P50

Technical specifications:
Model Number ADV551-P50
Brand Yokogawa
Type Safety Digital Input Module
Input Type 24V DC (Sink/Source)
Channels 16 (Dual-channel redundant)
Safety Certification SIL3 (IEC 61508), TÜV Rheinland
Response Time < 50 ms (configurable)
Operating Temp Range -20°C to +60°C
Mounting ProSafe-RS I/O Unit
Diagnostics Channel faults, wire breaks, short circuits
Power Consumption 2.5 W (typical)
Compliance CE, ATEX, IECEx

 

contact us:
Phone:+86 16626708626
WeChat/WhatsApp:+86 16626708626
Email: 3772179818@qq.com

ADV551-P50

ADV551-P50

Main features and advantages:

Choosing the YOKOGAWAADV551-P50 means investing in operational safety and reliability. Its dual-channel architecture with discrepancy detection prevents nuisance trips while maintaining the highest safety integrity – crucial for avoiding costly process shutdowns. Engineers appreciate the module’s transparent diagnostics, which reduce troubleshooting time by clearly identifying whether an issue stems from field devices, wiring, or the module itself. The SIL3 certification provides peace of mind for safety system designers, knowing the module meets the most stringent requirements for risk reduction. For plant operators, the hot-swappable capability means maintenance can be performed without compromising overall system safety, as redundant modules continue protection during replacement. The module’s wide operating temperature range and robust construction ensure reliable performance even in harsh plant environments.

ADV551-P50

ADV551-P50

 

Application areas:
In offshore oil platforms, theADV551-P50 processes signals from emergency shutdown valves and gas detection systems where failure could have catastrophic consequences. Power generation facilities rely on it for turbine overspeed protection and boiler safety interlocks, where response time and reliability are paramount. For pharmaceutical manufacturers operating in hazardous areas, the module’s ATEX certification ensures compliance while monitoring critical equipment status. Across these applications, the module’s combination of safety certification, diagnostic capabilities, and rugged design make it the preferred choice for engineers who cannot compromise on safety system performance.
Related products:
ADV551-T50 – TMR (Triple Modular Redundant) version for ultra-high availability systems
ADV161-P50 – 32-channel version for high-density digital input requirements
AAV551-P50 – Analog input counterpart for safety-related process variables
ADV552-P50 – Digital output module for safety actuator control
ADV571-P50 – HART-enabled version for smart device integration
Installation and maintenance:
Prior to installation, verify compatibility with your ProSafe-RS controller version (requires R4.01 or later). Use appropriately rated cables for safety applications, and pay special attention to segregation between safety and non-safety wiring. During commissioning, utilize Yokogawa’s Safety Engineering Tool to configure appropriate discrepancy times and filter settings for your specific application. Routine maintenance should include quarterly verification of LED indicators and annual checks of terminal tightness.
For systems operating in corrosive environments, consider more frequent inspections of field connections. Always maintain proper documentation of any module replacements or configuration changes for safety system audits.
Other product models of Yokogawa:
YOKOGWA AFV30D-A41252
Yokogawa SCP451-51
YOKOGWA TDLS8000
YOKOGWA 2104B2081
YOKOGWA AIP830-111/VESA
YOKOGWA AFV30D-A41152
YOKOGWA AAI143-H50/K4A00
YOKOGWA AAP135-S50
YOKOGWA ANB10D-415/CU2T
YOKOGWA ANB10D-415/CU2N