Sale!

REM543BM215AAAB Enhanced Multifunctional Numerical Protection Relay

The REM543BM215AAAB is a high-performance, numerical generator protection relay belonging to ABB’s Relion® 543 product line. This specific variant (BM215AAAB) indicates a configuration tailored for demanding marine and industrial duties, often featuring enhanced environmental ratings. It acts as the primary protection device for a generating asset, integrating multiple protection, control, and monitoring functions into a single, compact IED (Intelligent Electronic Device).

Categories: , , , , Brand:

Description

Real-World Use & Application Scenarios

In the demanding environment of a marine vessel’s electrical network or an offshore platform’s power distribution, system stability and equipment protection are non-negotiable. These isolated grids cannot tolerate a protection failure, as a single fault could lead to a complete blackout, jeopardizing safety, operational continuity, and critical loads. The REM543BM215AAAB is engineered for precisely these mission-critical, mobile, and harsh environment applications. It serves as the intelligent sentinel for a generator or a large HV/LV transformer, continuously monitoring electrical parameters like current, voltage, and frequency. In a scenario where a ship’s main generator experiences a sudden stator fault or a loss of excitation, this relay is designed to detect the anomaly within milliseconds and initiate a precise trip command to the circuit breaker, isolating the generator to prevent catastrophic mechanical and electrical damage. Its robust construction and specific certifications make it applicable in marine and offshore control systems where reliability under duress, resistance to vibration, and operation in saline atmospheres are fundamental requirements.

Product Introduction & Positioning

The REM543BM215AAABis a high-performance, numerical generator protection relay belonging to ABB’s Relion® 543 product line. This specific variant (BM215AAAB) indicates a configuration tailored for demanding marine and industrial duties, often featuring enhanced environmental ratings. It acts as the primary protection device for a generating asset, integrating multiple protection, control, and monitoring functions into a single, compact IED (Intelligent Electronic Device). Its role is to safeguard the generator from a comprehensive range of electrical faults, including internal short circuits, unbalanced currents, over-excitation, and reverse power. For system integrators and marine engineers, the value of the REM543BM215AAAB lies in its application-focused design and compliance with stringent classification society rules. It consolidates what would traditionally require several discrete relays, simplifying system design, reducing panel space, and providing a unified interface for configuration and diagnostics, which is crucial in space-constrained engine control rooms.

Key Technical Features & Functional Benefits

The REM543BM215AAAB delivers robust protection through a suite of advanced, generator-specific functions. A core strength is its comprehensive differential protection (87G), which provides fast and sensitive detection of internal phase-to-phase and phase-to-ground faults within the generator stator winding. This is complemented by highly secure backup overcurrent protection (51V/50V) and critical reverse power protection (32), which prevents a generator from motoring and being damaged if the prime mover fails. The relay incorporates advanced logic and voltage-restrained elements that ensure stability during external faults and system disturbances while maintaining the speed needed for internal faults.

From a hardware and certification standpoint, this relay is built for resilience. The “BM” designation often signifies a robust metal housing and components selected for extended temperature ranges and resistance to shock, vibration, and humidity, aligning with standards from classification bodies like DNV GL, ABS, and Lloyd’s Register. Its communication capabilities are a significant benefit, supporting protocols like IEC 61850 and Modbus TCP for seamless integration into a vessel’s integrated automation system (IAS) or a plant’s SCADA. This allows for remote monitoring of operational status, real-time metering data, and detailed sequence of events (SOE) logging, turning the REM543BM215AAAB into a central data hub for the generator’s health and performance.

REM543BM215AAAB
REM543BM215AAAB
REM543BM215AAAB
REM543BM215AAAB

Detailed Technical Specifications

Parameter Value
Model REM543BM215AAAB
Brand ABB
Type Numerical Generator Protection Relay (IED)
Power Supply 24-48 V DC / 80-265 V AC/DC (Wide Range)
Operating Temperature -25 to 70 °C (-13 to 158 °F)
Mounting Flush Mounting (Panel)
Dimensions 1/2 Rack (Approx. 128mm x 126mm x 119mm)
Weight Approx. 1.2 kg
Inputs 3 Phase Current (CT), 1 Ground Current (CT), 3 Phase Voltage (VT)
Outputs 7 Programmable Relays (NO/NC)
Communication 2 x Ethernet (IEC 61850, Modbus TCP), 1 x RS485
Certifications cULus, DNV GL, ABS, Lloyd’s Register, IEC 60255
Disturbance Recording Yes, with oscillographic and event data

Related Modules or Compatible Units

REM543 – The base series model for standard industrial applications without marine certifications.
REG670 – A more advanced generator protection terminal for larger utility-scale generators.
RET670 – A transformer protection relay, often used in conjunction to protect the main step-up transformer.
REC615 – A feeder protection and bay controller for the switchgear feeding from the generator.
CMC 256 Plus – A universal test set used for commissioning and testing the protection functions of the REM543BM215AAAB.

Installation Notes & Maintenance Best Practices

Correct installation is paramount for the reliable performance of the REM543BM215AAAB. The relay should be mounted on a solid, flat surface within a control panel, ensuring it is securely fastened to withstand the vibrations typical in marine environments. Special attention must be paid to the Current Transformer (CT) circuits; the CTs must be correctly sized and classed for protection, and their secondary circuits must never be open-circuited while the primary system is energized. For the differential protection (87G) to function correctly, the CT polarities must be strictly observed according to the wiring diagram. All cable shields should be continuous and grounded at a single point to prevent ground loops and mitigate electromagnetic interference.

Maintenance for the REM543BM215AAAB is streamlined by its comprehensive self-diagnostics and data logging. The relay itself requires no periodic calibration. The primary maintenance activity involves regularly reviewing its stored data. After any trip event or alarm, the sequence of events (SOE) and detailed fault records should be downloaded and analyzed to verify the relay’s operation and understand the system event. During planned generator outages, a secondary injection test using a certified relay test set should be performed to verify the accuracy of all protection elements and the correct operation of binary inputs and outputs. Keeping a backup of the relay’s configuration file is a critical best practice for rapid recovery.