Sale!

Prosoft MVI56E-MCM High Performance Communication Module

Prosoft MVI56E-MCM is a high-performance communication module designed specifically for the Allen Bradley ControlLogix platform. It is like a multifunctional translator that can convert data between various industrial protocols, including Modbus RTU, Modbus TCP, and Ethernet/IP. This module is equipped with one Ethernet port and two serial ports (RS-232/422/485), which can flexibly connect various devices.

Model MVI56E-MCM
Brand Prosoft
Type ControlLogix Communication Module
The input voltage is powered by the ControlLogix backplane
Working temperature range: 0 ° C to 60 ° C
Installation method: Install on the ControlLogix backplane
Interface/Bus: One Ethernet port and two serial ports (RS-232/422/485)
Supported protocols include Modbus RTU, Modbus TCP, Ethernet/IP

Description

Prosoft MVI56E-MCM is a high-performance communication module designed specifically for the Allen Bradley ControlLogix platform. It is like a multifunctional translator that can convert data between various industrial protocols, including Modbus RTU, Modbus TCP, and Ethernet/IP. This module is equipped with one Ethernet port and two serial ports (RS-232/422/485), which can flexibly connect various devices.

MVI56E-MCM

MVI56E-MCM

Ethernet ports can achieve seamless integration with modern control systems and network infrastructure, supporting multiple industrial Ethernet protocols. Meanwhile, the two serial ports can be configured to support various serial communication protocols, enabling theMVI56E-MCM to interface with old sensors, actuators, and other devices that use serial communication. Engineers can use Prosoft’s intuitive programming tools to configure module firmware, define communication parameters, data mapping, and protocol settings based on the specific requirements of their application.

MVI56E-MCM

MVI56E-MCM

Technical specifications:
Model MVI56E-MCM
Brand Prosoft
Type ControlLogix Communication Module
The input voltage is powered by the ControlLogix backplane
Working temperature range: 0 ° C to 60 ° C
Installation method: Install on the ControlLogix backplane
Interface/Bus: One Ethernet port and two serial ports (RS-232/422/485)
Supported protocols include Modbus RTU, Modbus TCP, Ethernet/IP

 

Contact Us
Phone:+86 16626708626
WeChat/WhatsApp:+86 16626708626
Email: 3772179818@qq.com

MVI56E-MCM

MVI56E-MCM

Main features and advantages:
This module is designed for harsh industrial environments and has excellent reliability, ensuring stable performance even under extreme working conditions such as temperature, humidity, and electrical interference. It supports multiple protocols without the need for multiple dedicated communication devices, significantly reducing hardware costs and simplifying system architecture.

MVI56E-MCM also simplifies the integration process. With Prosoft’s user-friendly software tools, engineers can quickly and easily configure modules, reducing the time and effort required for system setup. This helps accelerate project deployment and enables the company to realize the benefits of automation upgrades more quickly. In addition, the built-in diagnostic function of the module improves maintenance efficiency. By providing detailed information on communication status and potential issues, it can achieve proactive maintenance, minimize unplanned downtime, and improve the normal operation time of critical industrial processes. Overall, Prosoft MVI56E-MCM is an economically efficient and reliable solution that enables engineers to build more efficient and interconnected industrial automation systems.

MVI56E-MCM

MVI56E-MCM

Application areas:
In manufacturing, it is commonly used to integrate old production equipment with modern control systems. For example, it can connect old conveyor belts with serial based control panels to new Ethernet based manufacturing execution systems for seamless data exchange and centralized control. This integration improves the efficiency, quality control, and overall flexibility of the production line.

In the energy industry, especially in power plants, MVI56E-MCM plays a key role in coordinating different components of the power generation and distribution system. It can communicate with various sensors, actuators, and intelligent electronic devices (IEDs) using different protocols to ensure smooth operation and reliable power supply. Similarly, in the oil and gas industry, remote monitoring and control are crucial. This module enables communication between on-site equipment and the central control room, facilitating real-time data collection and analysis, and improving safety and operational efficiency.

MVI56E-MCM

MVI56E-MCM

Related products:
Prosoft MVI56E-MCMR: Provides redundancy functionality to provide higher reliability for applications that require extremely high system uptime. Applicable to critical processes that cannot tolerate communication failures.
Prosoft MVI56E-MNET: focuses on communicating with Allen Bradley MicroLogix controllers through Ethernet networks, with specific protocol support for such settings.
Prosoft MVI56E-PDPS: specifically designed for communication from EtherNet/IP to PROFIBUS DP, suitable for applications involving PROFIBUS based devices and systems.
Prosoft MVI69E-MCM is designed specifically for use with other control platforms, providing an alternative to non ControlLogix based automation systems.

 

 

Installation and maintenance:
Before installing Prosoft MVI56E-MCM, make sure it is compatible with the existing Allen Bradley ControlLogix system. Check if the ControlLogix backplane has available slots and can provide necessary power to the module. Check the firmware versions of MVI56E-MCM and ControlLogix controllers, and update them to the latest version if necessary, as firmware updates typically include performance enhancements, error fixes, and security improvements.

For continuous maintenance, regularly monitor the diagnostic indicator lights on MVI56E-MCM. These indicator lights provide valuable information about communication status, error occurrence, and overall module health. Regularly check Ethernet and serial connections to ensure their safety and no signs of damage or looseness. In addition, it is recommended to conduct regular communication testing, such as sending test packets between connected devices, to verify the integrity of the communication link and ensure reliable operation.