Sale!

HONEYWELL HCIX15-TE-FA-NC Humidity and Temperature Sensor

The Honeywell HCIX15-TE-FA-NC operates as a 15-inch touchscreen operator interface in the human-machine layer of Honeywell’s Experion PKS and ControlEdge ecosystems, visualizing controller data through custom graphics built in HC Designer or Builder tools.

Description

In process control environments where operators need intuitive, real-time visibility into complex systems to avert delays or misconfigurations during critical sequences, the Honeywell HCIX15-TE-FA-NC delivers a high-impact interface for engineers daunted by fragmented HMIs or protocol silos in hybrid automation stacks. Envision a distributed energy management setup in a manufacturing facility where sluggish screen updates from legacy consoles obscure turbine status or load shifts, sparking reactive tweaks that cascade into efficiency losses or safety overrides, or a chemical blending station where mismatched graphics hinder valve orchestration, inflating error rates in batch traceability—these hurdles typically emerge from panels that can’t fuse serial, Ethernet, and USB comms fluidly amid EMI or varying operator workflows. This 15-inch HCi series operator interface resolves them by rendering custom graphics on a vibrant TFT LCD touchscreen, supporting Experion PKS or ControlEdge Builder imports for drag-and-drop database syncing, ensuring seamless access to controller functions without custom coding or latency in high-stakes interactions.

It shines in industrial automation landscapes like process optimization or asset monitoring, where high reliability in HMI integration underpins agile decision-making and compliance with IEC 61131 standards for continuous operations. The Honeywell HCIX15-TE-FA-NC mounts into enclosures via VESA standards, embracing protocols like Ethernet TCP/IP and Modbus for bidirectional data pulls from PLCs or DCS nodes, so you bridge silos gracefully in zoned control rooms. For those scaling older TPS or third-party systems, it overlays without full retooling, easing adoption by preserving familiar touch gestures while boosting signal fidelity against 50 V common-mode noise. In expansive process control deployments, its analog-resistive touchscreen and 1024×768 XGA resolution handle gloved or multi-user sessions from -10°C to +50°C, facilitating expansions that absorb trending overlays without refresh lags. By prioritizing protocol versatility and graphical fluidity, the Honeywell HCIX15-TE-FA-NC enhances system stability, letting you achieve sharper operator throughput and reduced cognitive load that aligns with your goals for resilient, user-centric automation without the drag of bespoke development in demanding industrial landscapes.

When evaluating HMI upgrades for operator-heavy architectures, the Honeywell HCIX15-TE-FA-NC aligns for its screen real estate and import ease, providing the interface reliability that unifies control views in EMI-challenged or multi-protocol environments without sacrificing touch responsiveness.

The Honeywell HCIX15-TE-FA-NC operates as a 15-inch touchscreen operator interface in the human-machine layer of Honeywell’s Experion PKS and ControlEdge ecosystems, visualizing controller data through custom graphics built in HC Designer or Builder tools. It connects via Ethernet TCP/IP for primary comms, with serial/USB fallbacks for legacy ties, rendering up to 256-color TFT LCD displays at 1024×768 resolution for trends, alarms, or faceplates, supporting multi-touch gestures for navigation without stylus dependency. This setup enables database imports from Experion or third-party formats, syncing variables bidirectionally to PLCs or DCS without scripting, while diagnostics monitor link health or touch drift for proactive alerts.

HCIX15-TE-FA-NC
HCIX15-TE-FA-NC

In a typical stack, it draws 24 V DC from enclosures, interfacing downstream to controllers (e.g., C300) and upstream to SCADA for archiving, compatible with BACnet for building ties and redundancy for failover under 100 ms. It pairs with I/O modules for closed-loop visuals, like overlaying valve states on process mimics, adhering to UL 508 for panel integration. Positioned as the operator gateway in your I/O hierarchy, the Honeywell HCIX15-TE-FA-NC optimizes HMI architecture by consolidating views in a VESA-mountable unit, where Ethernet ports facilitate daisy-chaining in rooms—fostering a responsive pathway that scales with Profinet overlays, upholding graphic fidelity across topologies without introducing lag or reconfiguration burdens.

Specification Details
Model Number HCIX15-TE-FA-NC
Brand Honeywell
Type 15-inch Touchscreen Operator Interface
Input Voltage 24 V DC
Operating Temp Range -10°C to +50°C
Mounting Style VESA / Panel Mount
Dimensions 380 x 260 x 50 mm (W x H x D)
Weight 5.5 kg
Interface/Bus Ethernet TCP/IP, Serial, USB
Compliance CE, UL 508, RoHS
Supported Protocols Modbus, BACnet, Profinet
Typical Power Draw 25 W

Opting for the Honeywell HCIX15-TE-FA-NC equips your station with display dynamism that renders 1024×768 updates at 60 Hz without flicker, quashing the refresh lags that fragment operator focus and prolong anomaly hunts in multi-loop oversight, which in turn sharpens response times and trims errors in metrics like setpoint drifts or alarm acknowledgments. This vividness extends to import fluidity, where HC Designer pulls Experion maps for instant prototyping, often halving config cycles versus manual builds.

Touch diagnostics further refine upkeep, with drift alerts that surface calibration needs for swift alignments, minimizing downtime to minutes in monitored rooms versus hours for opaque panels. Its VESA form trims integration hurdles too—seating demands only Ethernet alignment, not bus reconfigs, which reallocates engineering from graphic hunts to workflow mapping. Built for room resilience, it withstands 5 g vibrations and 95% humidity with resistive tech, buffering surges to lock in long-term clarity, keeping your HMI attuned to control nuances through expansions or ambient shifts gracefully.

In power turbine control rooms, the Honeywell HCIX15-TE-FA-NC visualizes speed and vibration trends, where its resistive touch endures humid, EMI-laced bays to enforce critical system uptime and governor fidelity in continuous process control.

Chemical reactor consoles deploy it for batch sequencing mimics, handling fast data cycles amid thermal, vaporous zones to synchronize high-reliability dosing.

For wastewater treatment SCADA, this interface aggregates flow and pH graphics, meeting wet constraints with Ethernet ties that enable modular room growth in expansive I/O vaults.

HCIX15-TE-FD-NC – Fanless variant for dust-free enclosures with similar 15-inch display.

HCIX10-TE-FA-NC – 10-inch counterpart for compact operator stations.

HCIX15-TE-FA-PC – Normally closed to open contact config for alternate actuator ties.

C300M-P01 – Compatible C300 carrier for integrating with Experion nodes.

HCIXW15-TE-FA-NC – Widescreen 15-inch edition for landscape-oriented graphics.

CC-PDOD51 – Digital output module for hybrid I/O alongside the HMI.

HC Designer – Software tool for custom graphic imports and configuration.

Before mounting the Honeywell HCIX15-TE-FA-NC, confirm enclosure IP rating at NEMA 4X for humidity resistance, and torque VESA screws to 2 Nm to prevent wobble—loose fits amplify touch drift in vibratory rooms. Verify Ethernet cabling Cat5e shielded to cap EMI below 2 mV, and calibrate touch via built-in tools post-install to baseline responsiveness.

Sustaining it involves quarterly screen cleans with microfiber and isopropyl in dusty process areas to dispel fingerprints. Poll link stats bimonthly via the diagnostics menu to trend packet losses, addressing drops over 1% with cable swaps. Semiannual graphic integrity tests with simulated alarms confirm 60 Hz refresh, and archiving database files aids rapid restores. This measured routine syncs with your PM cadence, forestalling lags that unsettle operator harmony.