GE PRG-MODEM High performance communication equipment

GE PRG-MODEM is a high-performance communication device that supports multiple communication protocols. It is equipped with advanced modulation and demodulation technology, which can convert digital data into analog signals for transmission through various communication channels such as copper wires, fiber optic cables, or wireless frequencies, and then convert the received analog signals back into digital data.

Model number PRG-MODEM
Brand General Electric
Supported communication protocols include serial (RS-232, RS-485), Ethernet, Wi Fi, 3G/4G cellular
Advanced signal conversion technology for modulation/demodulation
Serial baud rate range 100-115200 bits/second
Ethernet speed 10/100/1000 Mbps
Cellular compatibility and compatibility with major cellular networks
Working temperature range -40 ° C to+70 ° C
Humidity range 5% -95%, no condensation

Categories: , , , , Brand:

Description

GE PRG-MODEM is a high-performance communication device that supports multiple communication protocols. It is equipped with advanced modulation and demodulation technology, which can convert digital data into analog signals for transmission through various communication channels such as copper wires, fiber optic cables, or wireless frequencies, and then convert the received analog signals back into digital data.

PRG-MODEM

PRG-MODEM

This modem supports multiple communication protocols, including but not limited to serial (RS-232, RS-485), Ethernet, and various wireless protocols such as Wi Fi and cellular (3G, 4G). For example, when communicating with traditional serial based devices, PRG-MODEM can establish a connection using its serial port. Then, it will modulate the digital data from these devices into appropriate analog signals for transmission through serial communication lines. At the receiving end, it will demodulate the incoming analog signal back into digital data for the connected system to understand.

PRG-MODEM

PRG-MODEM

Main features and advantages:
In terms of integration into industrial systems, GE PRG-MODEM can be installed in standard electrical cabinets. It interfaces with various industrial components such as programmable logic controllers (PLCs), human-machine interfaces (HMIs), sensors, and actuators. In typical industrial settings, PLCs may need to communicate with remote sensors located in different areas of the facility. PRG-MODEM can be connected to PLC and sensors. It will receive data from sensors, modulate it for transmission through communication media (e.g. wireless network if the sensor is located in a difficult to reach location), and then transmit the data to the PLC. Similarly, it can receive control commands from PLC, modulate them, and send them to relevant actuators to control their operation.
By supporting multiple protocols, it can quickly and accurately transmit data between different devices in industrial networks. In manufacturing plants with a large number of interconnected devices, this means that real-time data from sensors can be quickly transmitted to the control system. This enables operators to make timely decisions, such as adjusting production parameters based on changes in product quality or equipment performance. Therefore, it can improve production efficiency and better maintain product quality.

The robustness ofPRG-MODEM in harsh environments also brings cost savings. Due to its ability to operate reliably under extreme conditions, frequent replacement needs caused by environmental damage are reduced. In industries such as mining, equipment is exposed to dust, vibration, and extreme temperatures, and GE PRG-MODEM can operate continuously. This reduces the costs associated with equipment downtime and replacement, thereby improving overall profitability.

In addition, its flexibility in communication protocol support makes it an economical and efficient solution for both new and old industrial installation projects. It can be easily integrated into traditional systems without the need for large-scale modifications, allowing enterprises to upgrade their communication capabilities without incurring high costs. At the same time, it is also applicable to new projects, providing a future oriented communication solution that can adapt to constantly evolving technological requirements.

PRG-MODEM

PRG-MODEM

Technical specifications:
Model number PRG-MODEM
Brand General Electric
Supported communication protocols include serial (RS-232, RS-485), Ethernet, Wi Fi, 3G/4G cellular
Advanced signal conversion technology for modulation/demodulation
Serial baud rate range 100-115200 bits/second
Ethernet speed 10/100/1000 Mbps
Cellular compatibility and compatibility with major cellular networks
Working temperature range -40 ° C to+70 ° C
Humidity range 5% -95%, no condensation

 

Contact Us
Phone:+86 16626708626
WeChat/WhatsApp:+86 16626708626
Email: 3772179818@qq.com

PRG-MODEM

PRG-MODEM

Application areas:
Manufacturing: In automobile manufacturing, it is used to connect various components of the production line. For example, it can connect the PLC that controls the robotic arm on the assembly line with sensors that detect the position and quality of the assembled components. This ensures that the robotic arm can operate accurately, thereby achieving high-quality automotive production. In the food and beverage industry, PRG-MODEM can be used to monitor and control the filling and packaging process. It can communicate with sensors on the filling machine to ensure the correct quantity of product is filled into the container, and then transmit this data to the central control system for quality control.

Power generation industry: In power plants, whether coal-fired, hydro or wind power plants, GEPRG-MODEM plays a key role in monitoring and controlling the power generation process. It can connect sensors that measure parameters of power generation equipment, such as temperature, pressure, and voltage, to the central control system. By transmitting this data in real-time, it helps operators maintain the stability and efficiency of power generation. For example, if the sensor detects an abnormal increase in turbine temperature, the PRG-MODEMcan quickly transmit this information to the control system, allowing operators to take corrective measures before major problems occur.

Oil and gas industry: PRG-MODEM is used for communication between remote sensors and control centers in refineries and natural gas processing plants. These factories typically have large facilities with sensors located in hazardous areas. GE PRG-MODEM can establish reliable communication links even in the presence of electromagnetic interference and harsh environmental conditions. It can transmit data from sensors monitoring oil and gas flow, pressure, and composition to the control room, enabling operators to safely and efficiently manage the production process.

PRG-MODEM

PRG-MODEM

Installation and maintenance:
Before installing GE PRG-MODEM, be sure to carefully read the installation manual. Check the compatibility of the modem with existing industrial systems, including the communication protocol used for connecting devices, power requirements, and available installation space. Ensure that the electrical cabinet where the modem is installed has sufficient ventilation to prevent overheating, while considering the operating temperature range of the modem.

During the installation process, strictly follow the recommended wiring diagram for operation. When connecting the modem to other devices, use appropriate cables and connectors to ensure a safe and reliable connection. Take appropriate safety precautions, such as turning off the power supply of relevant system parts before connecting any lines, to avoid electric shock. According to the requirements of the device that the modem will communicate with, configure the settings of the modem, such as communication protocol, baud rate for serial connections (for serial connections), and network parameters for Ethernet and wireless connections.

For continuous maintenance, regularly check the PRG-MODEM for any signs of physical damage, such as cracked casing or loose connections. Use diagnostic tools to monitor the performance of the modem. Check the data transmission rate and error rate to ensure stable and reliable communication. Regularly test the functionality of the modem, send test data through the communication channel, and verify the received data. If any problems arise, please refer to the user manual or contact GE’s technical support team. They can provide guidance on troubleshooting common issues, such as communication errors caused by setup errors or interference.

 

 

Other GE product models:
GE HE693THM888K
GE IS420EWSBH3A
GE IS200TREAS1A
GE IC695CPE305
GE F650BFBF1G0HI6E
GE VMIVME-5565-110000
GE IC695CPU315-CD
GE IC695NKT002
GE IC695CPU315-CD
GE IS200TDBTH6ABC
GE IC800SSI228RD2
GE TKMA3Y1200
GE IS210MACCH1AKH
GE IS210BPPBH2CAA
GE IS210MACCH1AGG
GE IS200AEPCH1BAA
GE IS200WEMAH1AEA
GE IS200AEPAH1AHD
GE IS200WETAH1AEC
GE VMIVME-5565-010000 332-015565-010000 P
GE IC695ALG508-AA
GE DS200CPCAG1ABB
GE DS3800HFPB1F1E
GE DS3800NB1A
GE IC695ALG508
GE IC695ALG508
GE MIVII1000E00HI00
GE IC758CSWC19PCX512
GE XMTC-6C-11
GE WPX-08 WE3DNQGQEXBBXCX
GE 750-P5-G5-S5-HI-A20-R-E
GE 469P5HIA20EH
GE IC694PWR330
GE IC200ALG262
GE CK10CE300
GE IC755CBW07CDA
GE IS220PTURH1B
GE IS220PTURH1A
GE IS420UCSBS1A
GE IS200TDBSH6ABC
GE IS200STAIH1ABB
GE IS200SRTDH1ABB
GE IS420ESWB3HA
GE IS200JPDFG1A