Description
In the relentless domain of industrial automation, where a power supply failure can halt an entire Series 90-70 PLC rack, corrupt in-flight logic, or trigger unsafe actuator states, the margin for electrical instability is nonexistent. Engineers managing legacy DCS migrations, high-density I/O expansions, or safety-instrumented loops in Series 90-70 systems frequently face risks from aging PSUs that sag under load, lack diagnostics for impending faults, or force full-rack shutdowns for replacement—issues that drive unplanned outages, scrap, and audit failures. The GE IC697PWR710H confronts these squarely as a 55-watt, 120/240 VAC input power supply for GE Series 90-70 PLCs, delivering regulated +5 VDC, +12 VDC, and –12 VDC outputs with overvoltage protection and status reporting to sustain continuous, fault-tolerant control.
Envision a paper mill where a 90-70 rack orchestrates headbox, press, and dryer sections across 300 I/O points, or a power plant auxiliary system where a single PSU glitch could trip a turbine lube pump—the GE IC697PWR710H becomes indispensable when stable, monitored power underpins high-reliability process control. It resolves multi-voltage and diagnostic gaps by supplying +5 VDC @ 10 A for logic and backplane, +12 VDC @ 1 A and –12 VDC @ 0.5 A for analog and comms—all with individual current limiting and remote on/off control. In broader industrial automation contexts, it supports predictive maintenance via front-panel LEDs and PLC fault table entries for over-temperature, overload, and input loss. For specifiers, critical specs include its 85–264 VAC auto-ranging input, 90% efficiency, and rack-mount form factor—details that govern energy use, heat load, and retrofit ease. By fortifying the power core, the GE IC697PWR710H converts a legacy vulnerability into a monitored, resilient asset, enabling zero-downtime swaps and confident 24/7 operation in critical environments.
Embedding the GE IC697PWR710H into a Series 90-70 rack is like installing a vigilant substation at the system’s heart—it slides into the dedicated leftmost power supply slot of any 5-, 9-, or 17-slot baseplate, accepting universal AC input via a rear-mounted terminal strip. Outputs connect directly to the backplane bus bars: +5 VDC powers the CPU, I/O, and option modules; +12/–12 VDC support analog cards and serial ports. A front-panel key switch enables local on/off, while a remote enable pin allows PLC logic or external interlock control. Overvoltage crowbar circuits clamp outputs at 6.2 V, 15 V, and –15 V to protect downstream electronics.
In the power hierarchy, it sits upstream of all modules, with status feedback to the CPU via %S system bits and front-panel LEDs (POWER, OK, OVER TEMP, OVER LOAD). Thermal sensors trigger shutdown at 105°C with auto-restart, while current foldback limits protect against shorts. For redundancy, two GE IC697PWR710H units can parallel with external diodes, sharing load and providing N+1 failover—switchover occurs seamlessly without backplane droop. Picture the energy flow: 230 VAC enters, converts to regulated rails, and sustains a 9-slot rack with 40 W of I/O and a CPU364—all while the GE IC697PWR710H reports 78% load on +5 V rail to the HMI, prompting a preemptive hot-swap. For field teams, its slide-in design and finger-safe terminals minimize arc risk, making the GE IC697PWR710H the benchmark for Series 90-70 power resilience in process control.
- IC697PWR710H
- IC697PWR710H
| Specification | Details |
|---|---|
| Model Number | IC697PWR710H |
| Brand | GE (Emerson) |
| Type | 55 W AC Power Supply |
| Input Voltage | 85–264 VAC (47–63 Hz) |
| Operating Temp Range | 0°C to 60°C |
| Mounting Style | Series 90-70 Leftmost PSU Slot |
| Dimensions | 10.4 x 2.1 x 5.6 in (264 x 53 x 142 mm) |
| Weight | 2.2 lbs (1.0 kg) |
| Interface/Bus | Series 90-70 Backplane / Terminal Strip |
| Compliance | CE, UL, CSA |
| Supported Protocols | Native 90-70 Status (%S) |
| Typical Power Draw | N/A (Output: 55 W total) |
Opting for the GE IC697PWR710H yields immediate stability and long-term foresight—its 90% efficiency reduces heat by 30% versus older 100 W units, enabling full 17-slot racks without auxiliary fans, while regulated outputs hold ±2% under full load, preventing CPU resets during motor starts. Diagnostics shift maintenance from reactive to predictive: an OVER TEMP LED at 95°C signals dust buildup weeks before shutdown, enabling a hot-swap during a shift change.
Redundancy readiness delivers peace of mind—parallel two units, and a failed supply triggers an alarm but zero downtime, preserving I/O states and batch continuity. Commissioning simplifies with auto-ranging input—no jumpers for 120 vs. 240 VAC—and LED load indicators show headroom at a glance, avoiding over-provisioning. Over decades, the module’s >1M hour MTBF and field-replaceable fan defer capex; upgrade from a PWR710F with a 60-second swap, no rewiring. It’s a power solution that accrues value—lower cooling costs, predictive alerts, and scalable redundancy—making the GE IC697PWR710H the enduring backbone of Series 90-70 process control.
The GE IC697PWR710H powers continuous web handling in printing presses, where it feeds 90-70 racks with stable +5 VDC for registration control, its remote enable pin allowing emergency stops without full shutdown. In steel rolling mills, it supports high-density analog racks under 90% load, diagnostics catching input sags from welder inrush.
Municipal incinerators deploy it in remote PLC panels, where wide input range handles generator fluctuations, and hot-swap enables PSU replacement without SCADA loss. From glass melting to chemical distillation, the GE IC697PWR710H anchors industrial automation with monitored, redundant power that drives compliance and uptime.
IC697PWR711 – 100 W version for dense 17-slot racks
IC697PWR724 – 24/48 VDC input variant for battery-backed systems
IC697PWR710F – Legacy 55 W without remote enable
IC697CHS791 – 9-slot front-mount baseplate for PSU pairing
IC697ACC701 – ORing diode kit for redundant PSUs
IC697CBL700 – 3 m AC input power cable
IC697MDL740 – 16-point output module for load testing
IC697CPU781 – Scalable CPU for redundancy setups
Before mounting the GE IC697PWR710H, calculate rack load—sum all modules’ +5 V, +12 V, and –12 V draws; stay under 50 W for headroom. Use 14–16 AWG stranded copper for AC input, torque to 9 in-lbs, and route >12 inches from I/O cables. Pre-test input with a variac—ramp 85–264 VAC and confirm OK LED stays green. Set remote enable jumper if using PLC control. After insertion, latch securely and monitor LOAD LEDs—green <80%, amber 80–100%; if red, redistribute I/O or add a second PSU. For redundancy, install ORing diodes externally.
Maintenance is diagnostics-driven: weekly HMI check of %S bits for TEMP or OVERLOAD; log trends to predict fan life. Quarterly, cycle input power to verify hold-up time (>20 ms); measure output ripple with a scope (<50 mV p-p). In dusty plants, replace fan filter annually; swap fan assembly if delta-T >20°C. A persistent FAULT usually traces to input surge—install a line filter if transients exceed 300 V. This lean, predictive cadence keeps the GE IC697PWR710H as a silent guardian, ensuring power never compromises legacy 90-70 control.




WhatsApp: +86 16626708626
Email:
Phone: +86 16626708626