Description
The EnerMech EMP2200 operates as an advanced energy management and power monitoring device, integrated into the industrial power distribution network. It continuously collects data on key electrical parameters such as voltage, current, power factor, energy consumption, and harmonic distortion from multiple points in the system. This data is processed and analyzed in real time, with insights delivered through an intuitive user interface that allows for easy visualization of energy trends and identification of inefficiencies. The device connects seamlessly to existing SCADA systems and building management platforms via standard communication protocols, enabling centralized control and monitoring.
EMP2200
What sets the EnerMech EMP2200 apart is its ability to handle high-speed data acquisition, capturing up to 1000 samples per second, which ensures accurate measurement even in dynamic industrial environments where power usage fluctuates rapidly.
EMP2200
Technical specifications:
Model Number EMP2200
Brand EnerMech Industrial
Type Energy Management & Power Monitoring Device
Input Voltage 3-phase 380-480V AC
Operating Temp Range -20°C to +60°C
Mounting Style DIN Rail / Panel Mount
Dimensions 160mm x 100mm x 75mm
Weight 550g
Interface/Bus Ethernet/IP, Modbus TCP/IP
Compliance CE, RoHS, IEC 61557
Supported Protocols
Modbus, BACnet, MQTT
Typical Power Draw 5W
Contact Us
Phone:+86 16626708626
WeChat/WhatsApp:+86 16626708626
Email: 3772179818@qq.com
EMP2200
Main features and advantages:
Choosing the EnerMech EMP2200 brings significant real-world benefits to industrial operations. Its precise energy monitoring capabilities allow facilities to identify energy waste, optimize equipment scheduling, and reduce overall energy consumption, leading to substantial cost savings over time. By providing real-time data on power quality, the device helps prevent equipment damage caused by poor power conditions, reducing maintenance costs and unplanned downtime. The EnerMech EMP2200 also simplifies compliance with energy regulations and sustainability standards, as it generates detailed reports on energy usage and carbon footprint, making it easier to meet environmental targets. Additionally, its user-friendly interface and customizable dashboards mean that even non-technical staff can quickly understand energy data, facilitating informed decision-making across the organization.
EMP2200
Application areas:
The EnerMech EMP2200 excels in a variety of industrial settings where energy management is critical. In large manufacturing facilities, it monitors power usage across production lines, identifying opportunities to shift energy-intensive processes to off-peak hours, thereby reducing electricity costs. In data centers supporting industrial automation systems, the EnerMech EMP2200 ensures efficient power distribution to servers and cooling systems, preventing overloads and optimizing energy usage to maintain reliable operation. It is also widely used in pharmaceutical plants, where precise power monitoring is essential to ensure compliance with strict regulatory requirements for equipment operation and energy usage. In each of these applications, the device’s ability to handle high data rates and provide accurate measurements in varying operating conditions makes it a valuable asset.
Related products:
Before installing the EnerMech EMP2200, ensure that the power supply to the installation location is stable and within the device’s input voltage range. Check that the communication network has sufficient bandwidth to handle the data flow from the device, especially if multiple units are being installed. Verify that the mounting surface can support the device’s weight and provides adequate space for wiring and ventilation—at least 15mm of clearance on all sides.
For ongoing maintenance, regularly check the device’s status indicators to ensure proper operation—steady green indicates normal functioning, while a flashing red light signals an issue that requires attention. It is also recommended to perform a monthly calibration check using a standard reference meter to maintain measurement accuracy. Additionally, keep the device’s firmware up to date by downloading the latest versions from the manufacturer’s website to access new features and security updates.
Other product models:
REXROTH 4DMC160
GE 350-E-P1-G1-H-E-S-C-P-SN-D-N
Woodward 9907-135
ABB 216EA62
Emerson NTM-212-CBNS-0000
PROSOFT 5302-MBP-MCM4
AMAT SD1024F-2-S
KONGSBERG AKM32S-ASSNS-05
ABB 216EA62
ABB 216EA62
ABB 216EA62 1MRB150083R1/F
Emerson A6370D
DEIF PPU/2/GS
DELEM DM-103VA
ABB 216MB66 HESG324510M1
ABB 216NG62A HESG441634R1/K HESG216876
ABB 216NG63A HESG441635R1 HESG216879/K
ABB 216V62a HESG324442R13/B
ABB 216VC62a HESG324442R112/F
Baikale 8MSA3X.R0-30
WOODWARD 9907-014
WOODWARD 8440-2165
B&R 8MSA3X.R0-30
Emerson CE3007
ABB 216VC62a HESG324442R112/F
REXROTH HDS02.2-W040N-HS32-01-FW
Eaton XV-230-57CNN-1-13-1
WOODWARD 8405-094
ABB 216VC62a HESG324442R112/F
WOODWARD SPM-D2-10 8440-2066A
Eaton XV-440-10TVB-1-50
OMNI 6000-1D-1SE-1A-2SV
ABB 216VC62a HESG324442R13/B
ABB 216VC62A HESG324442R112/F
NI SBRIO-9627
Renishaw RLU10-A3-A3
BENTLY 3500/65-01-00 145988-02
WARNER MCS2000-ECA
WARNER MCS2000-DRV2
MECS CS-1000A
A-B 80026-529-01-R
ABB 216VC62A HESG324442R13
GE 5266222-2 – GSCB GOC6.6
LAM 810-135227-010
LAM 810-240888-002
LAM 810-107813-306
yokogawa ALP111-S001
Eaton XVH-340-57CAN-1-50
ABB 216VC62A HESG324442R13
Emerson A6125 9199-00069
Emerson A6210 9199-00003
ABB 216VC62A HESG324442R13