Description
The EMERSON 5X00121G01 is predominantly used in process automation environments such as power generation, oil and gas, chemical, and refining industries where precise temperature monitoring is essential. This product is designed to interface with Resistance Temperature Detectors (RTD), gathering accurate temperature data to support process control and safety systems. The EMERSON 5X00121G01 module is applicable in control systems requiring multi-channel temperature input, delivering reliable sensor data for real-time monitoring and automation decision-making. Its role is critical in applications where maintaining specific thermal conditions ensures product quality, protects equipment integrity, and maximizes operational efficiency. In demanding industrial settings, such as turbine control or chemical reactors, this module facilitates continuous temperature measurement and alerts operators to deviations, thereby enhancing process stability and safety.
The EMERSON 5X00121G01 is an 8-channel RTD input module designed for the Ovation Distributed Control System (DCS) platform by Emerson. It is engineered to interface with multiple RTD sensors commonly used for temperature measurement across industrial processes. This module supports the Ovation DCS architecture by providing precise, high-resolution temperature data feeds from field RTDs into the control system’s processing units. It is integrated into Ovation racks or enclosures, communicating with the system controller via a dedicated backplane and communication protocol. The 5X00121G01 module enables seamless temperature monitoring for a variety of processes, contributing to the overall system’s control fidelity and responsiveness. Its value lies in delivering consistent, accurate temperature readings with minimal noise and error, providing operators and engineers confidence in their process control metrics.
- 5X00121G01
The EMERSON 5X00121G01 distinguishes itself through its technical capabilities tailored to high-precision temperature sensing. It features eight independent RTD input channels capable of supporting commonly used platinum RTDs such as Pt100 and Pt1000, with an operating temperature range from -200°C to 800°C. The module offers accuracy within ±0.1% of full scale, ensuring reliable temperature data even in critical applications. Its hardware design emphasizes noise reduction and signal stability, employing advanced filtering techniques to minimize interference from industrial environments. Compact yet rugged, the module fits into standard Ovation system racks, designed to operate in ambient temperatures ranging from -40°C to +70°C, making it suitable for harsh plant conditions. Its compatibility with Emerson’s Ovation controllers streamlines system integration and upgrades. Long-term, the 5X00121G01 delivers stable performance and durability, backed by Emerson’s quality manufacturing, reducing downtime and maintenance needs.
Parameter | Value |
---|---|
Model | 5X00121G01 |
Brand | Emerson |
Product Type | 8-Channel RTD Input Module |
Supported Sensor Types | Pt100, Pt1000 RTDs |
Temperature Range | -200°C to +800°C |
Accuracy | ±0.1% of full scale |
Input Voltage | 24 VDC (typical Ovation system) |
Operating Temperature | -40°C to +70°C |
Dimensions (HxWxD) | Approx. 13 cm x 5 cm x 15 cm |
Communication Interface | Backplane communication for Ovation DCS |
Noise Reduction Features | High-quality filtering |
Mounting | Ovation rack mount |
Certifications | CE, UL (system dependent) |
Related Emerson Ovation modules often used alongside the 5X00121G01 include:
5X00119G01 – Complementary input module supporting different sensor types or signal conditioning.
5X00123G01 – Analog output module for controlling actuators based on sensor feedback.
5X00120G01 – Digital input module for discrete signals integration in Ovation systems.
5X00122G01 – Analog input module designed for voltage and current sensor inputs.
5X00124G01 – Output control module used to regulate valves and other field devices.
Before installing the EMERSON 5X00121G01, ensure that the Ovation rack or cabinet has the proper space and backplane connectivity to accommodate the module. Verify grounding and shielding practices to reduce signal noise and improve measurement fidelity. Maintenance should focus on regularly checking input wiring and sensor connections for integrity and corrosion. Scheduled calibration of RTD sensors paired with the module is recommended to maintain measurement accuracy over time. Firmware updates may be required in alignment with the Ovation system controller, ensuring compatibility and feature enhancements. Proper environmental controls within the equipment room can extend the module’s service life.