Sale!

ECU01.5 Edge Communication Unit

The ProTech ECU01.5 operates as an edge communication unit, serving as a protocol translator and data concentrator in the automation stack. It sits between field devices—such as sensors, actuators, and motor drives—and the primary control bus, converting between legacy protocols (like Modbus ASCII) and modern industrial Ethernet standards (including EtherCAT and PROFINET). This bidirectional translation allows older equipment to integrate with newer control platforms without costly hardware replacements.

Model Number ECU01.5
Brand ProTech Industrial
Type Edge Communication Unit
Input Voltage 12-24V DC ±15%
Operating Temp Range -25°C to +60°C
Mounting Style Panel Mount / DIN Rail
Dimensions 150mm x 100mm x 75mm
Weight 420g
Interface/Bus Dual Ethernet ports, RS-485
Compliance CE, RoHS, IEC 61010
Supported Protocols PROFINET, EtherCAT, Modbus RTU/ASCII, Ethernet/IP
Typical Power Draw 5W

 

Categories: , , , , , Brand:

Description

The ProTech ECU01.5 operates as an edge communication unit, serving as a protocol translator and data concentrator in the automation stack. It sits between field devices—such as sensors, actuators, and motor drives—and the primary control bus, converting between legacy protocols (like Modbus ASCII) and modern industrial Ethernet standards (including EtherCAT and PROFINET). This bidirectional translation allows older equipment to integrate with newer control platforms without costly hardware replacements.

ECU01.5

ECU01.5

What distinguishes the ProTech ECU01.5 is its parallel processing architecture, which handles up to 16 concurrent data streams without latency, ensuring time-critical signals reach the control system in milliseconds. It connects via a redundant backplane interface, supporting hot-swap functionality that lets maintenance teams replace the unit without halting production—a feature that’s become indispensable in 24/7 manufacturing environments.

ECU01.5

ECU01.5

Technical specifications:
Model Number ECU01.5
Brand ProTech Industrial
Type Edge Communication Unit
Input Voltage 12-24V DC ±15%
Operating Temp Range -25°C to +60°C
Mounting Style Panel Mount / DIN Rail
Dimensions 150mm x 100mm x 75mm
Weight 420g
Interface/Bus Dual Ethernet ports, RS-485
Compliance CE, RoHS, IEC 61010
Supported Protocols PROFINET, EtherCAT, Modbus RTU/ASCII, Ethernet/IP
Typical Power Draw 5W

 

Contact Us
Phone:+86 16626708626
WeChat/WhatsApp:+86 16626708626
Email: 3772179818@qq.com

ECU01.5

ECU01.5

Main features and advantages:

Selecting the ProTechECU01.5delivers operational advantages that directly impact the bottom line. Its ability to unify diverse protocols reduces the need for multiple communication gateways, streamlining system architecture and cutting down on hardware costs. Engineered for industrial longevity, the unit’s ruggedized casing and conformal coating protect internal components from dust, moisture, and vibration—ensuring long-term performance in harsh factory floors where lesser devices fail. Maintenance teams benefit from the ProTech ECU01.5’s intuitive web-based configuration interface, which eliminates the need for specialized programming software, reducing training time and simplifying setup. Perhaps most importantly, its redundant communication paths prevent single points of failure, ensuring that critical data continues to flow even if one network connection drops—an essential feature for maintaining process continuity in mission-critical applications.

 

ECU01.5

ECU01.5

Application areas:

The ProTech ECU01.5 proves its value across a range of demanding industries. In automotive manufacturing, it synchronizes robotic assembly arms with quality control sensors, ensuring real-time adjustments to welding parameters that prevent defects. Water treatment plants rely on the ProTech ECU01.5 to integrate legacy pump controllers with modern SCADA systems, maintaining precise flow rate monitoring essential for regulatory compliance. Pharmaceutical production facilities use the unit to connect cleanroom sensors with batch control systems, where data integrity is non-negotiable for meeting FDA documentation requirements. In each scenario, the ProTech ECU01.5 excels in environments requiring fast data cycles—processing up to 1,000 data points per second—and continuous uptime, with a mean time between failures (MTBF) exceeding 100,000 hours.

 

ECU01.5

ECU01.5

 

Related products:

ProTech ECU02.5 – Higher port density model supporting 32 concurrent data streams
ProTech ECU01.5-L – Low-power variant for battery-backed remote installations
ProTech ECU01.0 – Previous generation unit, still supported for legacy system compatibility
ProTech ECX01.5 – Expansion module adding wireless connectivity (Wi-Fi/Bluetooth)
ProTech ECP01.5 – Companion power supply unit with surge protection
ProTech ECU01.5-EX – ATEX-certified version for explosive atmospheres (Zone 2)
ProTech ECD01.5 – Diagnostic add-on for advanced network traffic analysis
Installation and maintenance:
Before installing the ProTech ECU01.5, confirm that the target network segment has sufficient bandwidth to handle the unit’s data throughput—at least 100Mbps for optimal performance. Check that existing devices on the network use protocols listed in the supported protocols matrix, as unsupported legacy formats may require a firmware update. Ensure the mounting surface can accommodate the unit’s heat dissipation—allow 10mm of clearance on all sides for passive cooling.
During setup, verify that IP addressing conflicts are resolved, as the ProTech ECU01.5 defaults to a static IP that may overlap with existing devices. For maintenance, schedule quarterly checks of Ethernet cable terminations to prevent corrosion-related signal loss, and review the unit’s event log monthly via the web interface to catch emerging issues like intermittent communication drops.
Other product models:
REXROTH 4DMC160
GE 350-E-P1-G1-H-E-S-C-P-SN-D-N
Woodward 9907-135
ABB 216EA62
Emerson NTM-212-CBNS-0000
PROSOFT 5302-MBP-MCM4
AMAT SD1024F-2-S
KONGSBERG AKM32S-ASSNS-05
ABB 216EA62
ABB 216EA62
ABB 216EA62 1MRB150083R1/F
Emerson A6370D
DEIF PPU/2/GS
DELEM DM-103VA
ABB 216MB66 HESG324510M1
ABB 216NG62A HESG441634R1/K HESG216876
ABB 216NG63A HESG441635R1 HESG216879/K
ABB 216V62a HESG324442R13/B
ABB 216VC62a HESG324442R112/F
Baikale 8MSA3X.R0-30
WOODWARD 9907-014
WOODWARD 8440-2165
B&R 8MSA3X.R0-30
Emerson CE3007
ABB 216VC62a HESG324442R112/F
REXROTH HDS02.2-W040N-HS32-01-FW
Eaton XV-230-57CNN-1-13-1
WOODWARD 8405-094
ABB 216VC62a HESG324442R112/F
WOODWARD SPM-D2-10  8440-2066A
Eaton XV-440-10TVB-1-50
OMNI 6000-1D-1SE-1A-2SV
ABB 216VC62a HESG324442R13/B
ABB 216VC62A HESG324442R112/F
NI SBRIO-9627
Renishaw RLU10-A3-A3
BENTLY 3500/65-01-00 145988-02
WARNER MCS2000-ECA
WARNER MCS2000-DRV2
MECS CS-1000A
A-B 80026-529-01-R
ABB 216VC62A HESG324442R13
GE 5266222-2 – GSCB GOC6.6
LAM 810-135227-010
LAM 810-240888-002
LAM 810-107813-306
yokogawa ALP111-S001
Eaton XVH-340-57CAN-1-50
ABB 216VC62A HESG324442R13
Emerson A6125 9199-00069
Emerson A6210 9199-00003
ABB 216VC62A HESG324442R13