The Watlow ANAFAZE CLS208 208-C10000CP operates as an 8-zone temperature controller, maintaining the same core functionality as the 208-C10000CA but with key upgrades for harsh environments. It interfaces with J, K, T, E thermocouples and PT100 RTDs, using adaptive PID algorithms to keep each zone within tight tolerances. What distinguishes it is its IP66-rated enclosure, which seals internal components against water ingress, chemical splashes, and particulate matter—critical for areas requiring daily sanitization with caustic cleaners.

Model Number CLS208 208-C10000CP
Brand Watlow
Type Multi-zone Temperature Controller (8 zones)
Input Voltage 85-264 VAC, 50/60Hz
Operating Temp Range -10°C to +60°C
Mounting Style Panel Mount (144 x 144 mm) with sealed bezel
Dimensions 144 mm x 144 mm x 135 mm (including seal)
Weight 0.9 kg
Interface/Bus RS-485, Ethernet/IP, Modbus RTU
Compliance CE, RoHS, UL 508, IP66
Supported Protocols Modbus RTU, Ethernet/IP, Profibus DP
Typical Power Draw 9W

Description

The Watlow ANAFAZE CLS208 208-C10000CP operates as an 8-zone temperature controller, maintaining the same core functionality as the 208-C10000CA but with key upgrades for harsh environments. It interfaces with J, K, T, E thermocouples and PT100 RTDs, using adaptive PID algorithms to keep each zone within tight tolerances. What distinguishes it is its IP66-rated enclosure, which seals internal components against water ingress, chemical splashes, and particulate matter—critical for areas requiring daily sanitization with caustic cleaners.

 

CLS208 208-C10000CP

CLS208 208-C10000CP

 

In the automation stack, this controller integrates seamlessly with PLCs, SCADA systems, and DCS via Ethernet/IP, RS-485, and Modbus RTU, just like its counterpart. However, the Watlow ANAFAZE CLS208 208-C10000CP adds specialized firmware that adjusts for temperature fluctuations caused by rapid environmental changes—such as post-washdown cool-down periods—ensuring zones recover quickly without overshoot. Its zone-to-zone synchronization remains intact, making it ideal for processes where timing is critical, even in harsh conditions.

CLS208 208-C10000CP

CLS208 208-C10000CP

Technical specifications:
Model Number CLS208 208-C10000CP
Brand Watlow
Type Multi-zone Temperature Controller (8 zones)
Input Voltage 85-264 VAC, 50/60Hz
Operating Temp Range -10°C to +60°C
Mounting Style Panel Mount (144 x 144 mm) with sealed bezel
Dimensions 144 mm x 144 mm x 135 mm (including seal)
Weight 0.9 kg
Interface/Bus RS-485, Ethernet/IP, Modbus RTU
Compliance CE, RoHS, UL 508, IP66
Supported Protocols Modbus RTU, Ethernet/IP, Profibus DP
Typical Power Draw 9W

Contact Us
Phone:+86 16626708626
WeChat/WhatsApp:+86 16626708626
Email: 3772179818@qq.com

CLS208 208-C10000CP

CLS208 208-C10000CP

Main features and advantages:

The Watlow ANAFAZE CLS208 208-C10000CP delivers tangible benefits in environments where durability directly impacts uptime. Its IP66 rating eliminates the risk of water or chemical damage during washdowns, reducing maintenance costs and extending service life compared to the 208-C10000CA. In facilities like meat processing plants, where daily high-pressure cleaning is mandatory, this controller continues operating without performance drops, ensuring temperature-critical processes—such as chilling or cooking stages—remain uninterrupted.
Beyond durability, the Watlow ANAFAZE CLS208 208-C10000CP maintains the precision that defines the CLS208 series. Its adaptive PID algorithms adjust for environmental variables like sudden temperature shifts from washdowns, preventing overshoot in sensitive processes like pharmaceutical compounding. For teams tasked with maintaining compliance in regulated industries, this controller simplifies validation by providing consistent performance data even in harsh conditions, reducing the burden of documentation and audits.

 

CLS208 208-C10000CP

CLS208 208-C10000CP

Application areas:

The Watlow ANAFAZE CLS208 208-C10000CP excels in industries where hygiene and durability are non-negotiable. In food and beverage processing—specifically dairy, meat, and beverage bottling—it regulates temperature zones in pasteurizers, fermenters, and cooling tunnels, withstanding daily washdowns using caustic agents. In pharmaceutical manufacturing, it controls multi-zone reactors and drying chambers, ensuring precise thermal profiles while resisting the sanitizing chemicals used in cleanroom maintenance.
It also finds applications in chemical processing facilities, where exposure to corrosive fumes or spills is common, managing temperature in mixing vessels and storage tanks. Its ability to maintain accuracy (±0.1°C) even after repeated exposure to harsh conditions makes it ideal for processes requiring both regulatory compliance and equipment resilience, such as in cosmetic production where sterility and temperature stability directly impact product quality.
CLS208 208-C10000CP

CLS208 208-C10000CP

 

Related products:

Watlow ANAFAZE CLS208 208-C10000CA – Standard multi-zone model for general industrial environments, lacking IP66 protection.
Watlow ANAFAZE CLS208 208-C10000CPX – Extended version of the 208-C10000CP with integrated pressure sensors for washdown monitoring.
Watlow ANAFAZE CLS204 204-C10000CP – Single-zone counterpart, designed for hygienic environments with fewer temperature zones.
Watlow ANAFAZE CLS208 208-C20000CP – Higher-power variant of the 208-C10000CP, supporting 20A per zone for larger heating elements.
Watlow ANAFAZE CLS208-SEAL – Replacement seal kit for the 208-C10000CP, ensuring long-term IP66 integrity.
Watlow ANAFAZE CLS208-COMMP – Communication module for the 208-C10000CP, adding wireless connectivity in a sealed enclosure.
Watlow ANAFAZE CLS108 108-C10000CP – Legacy hygienic model with limited protocol support, suitable for retrofitting older systems.
CLS208 208-C10000CP

CLS208 208-C10000CP

 

Installation and maintenance:

Before installing the Watlow ANAFAZE CLS208 208-C10000CP , inspect the mounting cutout to ensure it matches the 144 x 144 mm dimensions—any gaps around the bezel can compromise the IP66 seal. Verify that the panel surface is flat and free of debris; uneven surfaces may prevent the gasket from forming a tight seal. Check that the power supply delivers stable 85-264 VAC, as voltage spikes can affect both performance and the integrity of internal components.
For ongoing maintenance, visually inspect the bezel seal monthly for cracks or degradation, replacing it immediately if damage is found to maintain IP66 protection. Clean the front panel using only mild detergents—avoid abrasive cleaners that can damage the seal or display. While the controller is designed to resist corrosion, check terminal blocks quarterly for signs of chemical buildup, especially in environments with high humidity, and clean with a dry cloth if needed. Calibrate sensors annually using traceable standards to ensure the Watlow ANAFAZE CLS208 208-C10000CP  continues meeting precision requirements.

 

 

 

Other product models:

REXROTH 4DMC160
GE 350-E-P1-G1-H-E-S-C-P-SN-D-N
Woodward 9907-135
ABB 216EA62
Emerson NTM-212-CBNS-0000
PROSOFT 5302-MBP-MCM4
AMAT SD1024F-2-S
KONGSBERG AKM32S-ASSNS-05
ABB 216EA62
ABB 216EA62
ABB 216EA62 1MRB150083R1/F
Emerson A6370D
DEIF PPU/2/GS
DELEM DM-103VA
ABB 216MB66 HESG324510M1
ABB 216NG62A HESG441634R1/K HESG216876
ABB 216NG63A HESG441635R1 HESG216879/K
ABB 216V62a HESG324442R13/B
ABB 216VC62a HESG324442R112/F
Baikale 8MSA3X.R0-30
WOODWARD 9907-014
WOODWARD 8440-2165
B&R 8MSA3X.R0-30
Emerson CE3007
ABB 216VC62a HESG324442R112/F
REXROTH HDS02.2-W040N-HS32-01-FW
Eaton XV-230-57CNN-1-13-1
WOODWARD 8405-094
ABB 216VC62a HESG324442R112/F
WOODWARD SPM-D2-10  8440-2066A
Eaton XV-440-10TVB-1-50
OMNI 6000-1D-1SE-1A-2SV
ABB 216VC62a HESG324442R13/B
ABB 216VC62A HESG324442R112/F
NI SBRIO-9627
Renishaw RLU10-A3-A3
BENTLY 3500/65-01-00 145988-02
WARNER MCS2000-ECA
WARNER MCS2000-DRV2
MECS CS-1000A
A-B 80026-529-01-R
ABB 216VC62A HESG324442R13
GE 5266222-2 – GSCB GOC6.6
LAM 810-135227-010
LAM 810-240888-002
LAM 810-107813-306
yokogawa ALP111-S001
Eaton XVH-340-57CAN-1-50
ABB 216VC62A HESG324442R13
Emerson A6125 9199-00069
Emerson A6210 9199-00003
ABB 216VC62A HESG324442R13