Sale!

B&R 0GH-AT610 high-performance motion control module

The B&R 0GH-AT610 is a cornerstone for facilities leveraging older automation frameworks, such as injection molding or HVAC zoning, where its support for Type J/K thermocouples or Pt100 RTDs provides linearization and cold-junction compensation to deliver ±1°C accuracy across industrial spans. It’s particularly critical in vibration-exposed or thermally variable plants, offering burnout detection and open-circuit diagnostics that prevent silent failures common in unmonitored inputs.

Categories: , , , , Brand:

Description

In industrial automation landscapes, where seamless integration of analog signals into legacy PLC architectures is paramount to avoid data inaccuracies that could skew process variables or trigger unwarranted alarms, engineers frequently encounter obstacles like incompatible voltage ranges, insufficient channel density, or the rigidity of non-expandable I/O racks in established control systems. The B&R 0GH-AT610 tackles these head-on as a versatile analog temperature input module within the B&R System 2005 series, specifically engineered for precise acquisition of thermocouple and RTD signals to support temperature monitoring in process control environments. Consider a heat treatment furnace in a metal fabrication shop where multiple zone thermocouples must feed back to a central PLC for closed-loop regulation—if signal drift or channel crosstalk corrupts readings, you’d risk uneven heating, material defects, or safety interlocks that idle the line for hours. This module emerges as essential in such high-reliability setups, where its multi-channel configuration ensures accurate I/O signal processing, enabling modular expansions that maintain system stability without disrupting legacy B&R backplanes.

The B&R 0GH-AT610 is a cornerstone for facilities leveraging older automation frameworks, such as injection molding or HVAC zoning, where its support for Type J/K thermocouples or Pt100 RTDs provides linearization and cold-junction compensation to deliver ±1°C accuracy across industrial spans. It’s particularly critical in vibration-exposed or thermally variable plants, offering burnout detection and open-circuit diagnostics that prevent silent failures common in unmonitored inputs. By interfacing via the System 2005 bus, it simplifies scaling without custom converters, aligning with goals of enhanced diagnostics and reduced wiring overhead. In dusty or EMI-prone areas, its isolated channels shield against noise that could invalidate trends, fostering confidence in real-time adjustments. Keywords like “industrial automation,” “process control,” “I/O signal,” and “high reliability” align seamlessly—the B&R 0GH-AT610 bridges analog field data to PLC logic, minimizing the engineering toll for retrofits and upholding precision in environments where temperature fidelity directly influences quality and uptime.

0GH-AT610
0GH-AT610
0GH-AT610
0GH-AT610

The B&R 0GH-AT610 slots into the System 2005 backplane alongside base CPUs like the 3CP152, occupying a standard rack position to extend the I/O subsystem with up to 6 isolated thermocouple/RTD channels, converting raw millivolt or ohm inputs into scaled engineering units for the host processor via the proprietary bus. Positioned in the signal acquisition layer of the automation stack, it conditions signals through onboard amplifiers and A/D converters (16-bit resolution), supporting linearization tables for NIST-compliant curves while integrating with expansion modules for mixed-signal architectures. This setup interacts with the PLC kernel for cyclic polling, where each channel’s status— including fault flags for shorts or out-of-range values—is accessible via B&R’s programming tools, enabling integration with HMIs or SCADA for trend visualization without additional gateways.

In operation, the module draws 24 VDC from the backplane, with per-channel isolation up to 500 V to block ground potentials, and its jumper-selectable ranges (e.g., -200 to +1300°C for Type K) allow field tweaks without reconfiguration. For instance, in a plastics extruder, the B&R 0GH-AT610 might sample barrel temps from multiple Type J probes, compensating for ambient shifts to output linearized values at 100 ms intervals, while alerting on wire breaks to preempt melt inconsistencies—all synced to the CPU’s scan cycle. Its compatibility with System 2005’s multiprocessor RISC core ensures low-latency processing, and support for removable terminal blocks facilitates hot maintenance in live systems. This modular flow reduces enclosure clutter and enhances fault tolerance in bus-based designs, letting engineers emphasize control algorithms over input validation in the overarching process control framework.

Specification Details
Model Number 0GH-AT610
Brand B&R (Bernecker + Rainer Industrie-Elektronik)
Type Analog Temperature Input Module (System 2005 Series)
Input Voltage 24 VDC (backplane)
Operating Temp Range 0 to +60°C
Mounting Style Backplane/rack-mounted
Dimensions 25mm (W) x 100mm (H) x 120mm (D)
Weight 0.25 kg
Interface/Bus System 2005 bus, screw terminals
Compliance CE, UL, IEC 60364
Supported Protocols Proprietary System 2005 bus
Typical Power Draw 2 W

Selecting the B&R 0GH-AT610 equips your rack with a temperature sentinel crafted for enduring cycles, where its 16-bit conversion and CJC circuitry guarantee long-term performance by holding calibration across thermal gradients, allowing furnace zones to track setpoints with <0.5°C drift even amid 50°C ambient swings. In daily use, this means extruders maintaining melt uniformity without sporadic offsets that spawn defects, optimizing energy use and extending heater life—key for processes where precision underpins scrap reduction or compliance audits.

The module’s diagnostic integration further alleviates upkeep burdens, as bus-reportable faults enable predictive alerts via PLC logic, cutting troubleshooting from hours to minutes in distributed panels and easing the load on maintenance crews for multi-rack surveys. By supporting jumper-free range swaps post-install, it adapts to evolving sensor mixes without module pulls, aligning with lean paths for sub-30-minute interventions that preserve MTTR. For legacy-driven sites, the B&R 0GH-AT610 reframes inputs from accuracy liabilities to reliable informants, enhancing loop stability and scalability without fresh capital outlays.

In metal forging lines, the B&R 0GH-AT610 acquires die temps from Pt100 probes, its isolation thriving in forge-scale dust and inductive noise to deliver high reliability for process control—critical system uptime endures through burnout-proof channels that avert cracks in high-heat cycles.

Pharmaceutical drying ovens rely on the B&R 0GH-AT610 for batch uniformity, linearizing Type K signals in humid, cleanroom confines where its compact bus fit sustains process control accuracy, ensuring FDA-grade consistency without variance spikes.

Ceramics kilns deploy the B&R 0GH-AT610 for glaze monitoring, interfacing RTDs amid clay particulates and 1200°C exposures; its fault-tolerant design upholds high reliability, stabilizing firings for defect-free outputs in continuous kiln runs.

0GH-AT600 – Similar 4-channel variant for lighter temperature loads in compact racks.

0GH-AI300 – Analog input module alternative for voltage/current signals alongside temps.

0GH-DI425 – Digital input companion for hybrid signal processing in System 2005.

3CP152.9 – CPU module for primary control paired with 0GH-AT610 expansions.

0GH-EX301 – Bus extension unit to scale multiple 0GH-AT610 in larger backplanes.

0GH-PS740 – Power supply module for stable 24 VDC feeds to 0GH-AT610 setups.

0GH-DO650 – Digital output counterpart for temperature-based actuator responses.

Before slotting the B&R 0GH-AT610 into your System 2005 rack, confirm backplane seating with a continuity probe for pins under 0.2 ohms to nix bus glitches, and select jumpers per your thermocouple type (e.g., pins 1-2 for Type K) via the manual to match NIST tables—test linearity with a decade box at 0-100 mV. Verify 24 VDC stability under 50 mV ripple using a scope to forestall A/D noise, and torque terminals to 0.8 Nm for vibration hold; in humid bays, coat unused pins with conformal spray for corrosion resistance. Baseline channel offsets with a precision simulator at 25°C ambient, targeting <0.2°C error.

For the B&R 0GH-AT610, start checks with bi-monthly status scans via CPU diagnostics for open-circuit flags, calibrating a sample channel quarterly with a Fluke calibrator to ±0.5°C across span—adjust via software pots if drift exceeds 1°C, a rack-open task in 10 minutes. Semiannually, inspect terminals for oxidation in steamy spots, cleaning with isopropyl and re-torquing, and log fault incidences for trends. Annually, during process proofs, inject simulated breaks to confirm alert propagation under 200 ms, but offline: no live probes. These IEC 60364-aligned habits keep readings razor-sharp without rack raids.