Description
In the unforgiving arena of industrial automation, where hazardous zones demand power delivery that safeguards against sparks, surges, or ground faults without compromising the integrity of intrinsically safe (IS) circuits, engineers routinely confront risks like energy propagation that could ignite volatiles or disrupt safety interlocks in explosive atmospheres. The Allen-Bradley 1797-PS2E2 confronts these threats as a specialized Flex Ex power supply module, engineered to condition and isolate 24 VDC input into four low-energy, galvanically separated outputs for powering IS I/O modules in process control systems. Visualize a gas compressor station classified under ATEX Zone 1, where field sensors and actuators must remain energized amid methane pockets—if unregulated power breaches IS barriers, you’d invite arc flashes, false trips, or full ESD sequences that cascade into evacuations and lost output. This module is indispensable in such high-reliability environments, where its quad-Ex design ensures I/O signal precision by limiting each output to 9.5 VDC at 8.5 W, maintaining system stability without the vulnerabilities of bulk power feeds.
The Allen-Bradley 1797-PS2E2 is a safeguard for facilities navigating explosive risks, supporting modular integration with Flex Ex backplanes to extend safe power to up to 16 I/O channels without entity parameter violations. It’s a mainstay in scenarios like offshore drilling or pharmaceutical solvent handling, where its flameproof enclosure and removal-under-power capability allow hot connections in live zones, preventing the downtime from de-energized wiring. By embedding galvanic isolation at 250 V, it thwarts common hazards like common-mode voltages that erode barrier efficacy, streamlining compliance with IECEx and ATEX directives while easing diagnostics through status indicators. In vibration-laden or dust-choked sites, its IP65 sealing preserves output consistency, aligning with objectives of fault containment and lean field maintenance. Keywords such as “industrial automation,” “process control,” “I/O signal,” and “high reliability” define its domain—the Allen-Bradley 1797-PS2E2 anchors safe power distribution, enabling resilient operations in SIL 2-rated loops where energy control is the bedrock of hazard mitigation.
- 1797-PS2E2
The Allen-Bradley 1797-PS2E2 mounts directly onto the Flex Ex terminal base within a Zone 1/22 enclosure, interfacing with the IS backplane to feed conditioned power to downstream modules like digital inputs or barriers, while drawing from a non-hazardous 24 VDC source via M20 cable glands. Positioned as the power conditioning layer in the automation stack, it transforms incoming 18-32 VDC into four independent 9.5 VDC outputs—each capped at 900 mA to comply with IS entity rules—preventing excess energy from reaching field circuits in explosive gases or dusts. This configuration pairs seamlessly with Flex I/O adapters, where the module’s screw terminals handle input fusing and chassis grounding, ensuring equipotential bonds that suppress transients without dedicated isolators.
In a live setup, the Allen-Bradley 1797-PS2E2 supports hot-swapping via keyed connectors, allowing technicians to extend cabling in hazardous areas without shutdowns, while built-in LEDs signal output health and fault conditions for immediate visual triage. It integrates with control platforms like ControlLogix via remote I/O drops, relaying power status through the backplane for SCADA oversight, and its quad-output topology enables zoned distribution—say, dedicating channels to valve solenoids versus level transmitters—to optimize barrier loading. For instance, in a batch reactor skid, the module might energize proximity sensors across divided outputs, maintaining isolation to avoid cross-channel faults during solvent vapors—all while adhering to IEC 60079 parameters for Group IIC gases. This pragmatic placement minimizes gland penetrations and enhances expandability in IS architectures, letting engineers channel efforts into logic refinement over power logistics in the encompassing process control framework.
| Specification | Details |
|---|---|
| Model Number | 1797-PS2E2 |
| Brand | Allen-Bradley (Rockwell Automation) |
| Type | Flex Ex Intrinsically Safe Power Supply |
| Input Voltage | 24 VDC (18-32 VDC range) |
| Operating Temp Range | -20 to +70°C |
| Mounting Style | Terminal base-mounted (Zone 1/22) |
| Dimensions | 194mm (H) x 40mm (W) x 140mm (D) |
| Weight | 1.2 kg |
| Interface/Bus | M20 glands, IS backplane |
| Compliance | ATEX Zone 1/22, IECEx, IP65, IEC 60079 |
| Supported Protocols | N/A (power only) |
| Typical Power Draw | 1.6 A input (38 W max) |
Embracing the Allen-Bradley 1797-PS2E2 fortifies your IS backbone with a conditioner tuned for endurance, where its galvanic barriers sustain long-term performance by capping fault currents that might otherwise degrade module lifespans in cyclic thermal swings. In the heat of operations, this means sensors hold calibration across 9.5 V rails without voltage sag under 900 mA draws, averting the blind spots in gas detection that could escalate minor leaks—pivotal for processes where a single oversight invites regulatory halts or asset write-offs.
The module’s hot-insert design also eases field demands, as keyed slots prevent mismatch errors during expansions, trimming commissioning hours in confined enclosures and lightening the load on safety engineers for proof-testing. Maintenance refines further: output LEDs and fuse status enable spot audits without disassembly, aligning with IEC 61511 paths for annual verifications that clock in under an hour, fostering strategies where barriers stay proactive rather than reactive. For zones where safety intersects with uptime, the Allen-Bradley 1797-PS2E2 redefines power feeds from potential pitfalls to fortified lifelines, amplifying containment and compliance without ballooning enclosure counts.
In oil and gas wellheads, the Allen-Bradley 1797-PS2E2 energizes pressure transmitters and solenoid barriers, its quad outputs thriving in H2S-laced, 70°C confines with ATEX seals ensuring high reliability for process control—critical system uptime endures through isolated feeds that quash ignition risks during frac operations.
Chemical blending skids harness the Allen-Bradley 1797-PS2E2 for solvent level probes, distributing safe power in flammable vapor clouds where IP65 guards against condensation; its entity-limited channels uphold process control precision, stabilizing mixes without static discharges in batch runs.
Mining ventilation shafts deploy the Allen-Bradley 1797-PS2E2 to fan interlocks, powering dust-ignition-proof sensors under methane blooms and seismic jolts—its flameproof housing maintains high reliability, ventilating adits via vigilant I/O without blackout triggers in underground process control.
1797-PS1E2 – Single-output variant for lighter IS loads in compact Zone 2 setups.
1797-BI – Barrier interface module for pairing with PS2E2 in extended backplanes.
1797-IE8 – 8-channel analog input add-on for safe signal acquisition from PS2E2 feeds.
1797-DI8 – Discrete input module to populate Flex Ex racks powered by PS2E2.
1797-TB3 – Terminal base for Zone 1 mounting, complementing PS2E2 enclosures.
1797-OE8 – Analog output counterpart for actuator control in IS chains.
1715-PSAC – Redundant power supply alternative for non-Ex Flex I/O expansions.
Prior to energizing the Allen-Bradley 1797-PS2E2, cross-check entity parameters against your barrier certs via the Rockwell selector tool to confirm Group IIC compatibility, and measure input ripple under 200 mV at 24 VDC to avert output instability—use a scope on bench trials. Verify M20 gland torque at 25 Nm for 6-12 mm cables, ensuring IP65 seals with no gaps, and bond chassis ground to under 0.1 ohm per IEC 60079-14, especially in conductive dust zones. For ATEX, affix labels post-install and log initial output voltages at 9.5 VDC ±5% across channels with a precision meter.
Caring for the Allen-Bradley 1797-PS2E2 hinges on quarterly LED patrols for green output confirms, probing fuses with a DMM for continuity over 1 MΩ isolation—replace if open, a 5-minute gland-open task in de-classed areas. Semiannually, inspect cable entries for corrosion via borescope in humid haunts, re-torquing as needed, and pull diagnostic logs if integrated with PLC tags for trend spotting. Annually, during SIL audits, load-test each output to 900 mA with dummy loads to validate no creep beyond 10 mV drop, but bench it offline: live sparks are off-limits. These IEC 60079-17 measures keep barriers bulletproof without enclosure breaches.




WhatsApp: +86 16626708626