Sale!

ABB UNS0867 A-P V2 Control System I/O Module

Product Model: UNS0867 A-P V2
Product Brand: ABB
Product Series / Reference: UNITROL F / I/O Extension / Bailey / Control Module
Product Features (inferred):

  • I/O extension module supporting analog + digital signals (unlike the V1 version which is digital only)
  • Designed to be compatible with ABB UNITROL / AC800M / Bailey control systems
  • Standard form-factor “Bailey card” style, suitable for rack / backplane insertion
  • Listed with one-year warranty in aftermarket listings

Categories: , , , , Brand:

Description

Product Model: UNS0867 A-P V2
Product Brand: ABB
Product Series / Reference: UNITROL F / I/O Extension / Bailey / Control Module
Product Features (inferred):

  • I/O extension module supporting analog + digital signals (unlike the V1 version which is digital only)
  • Designed to be compatible with ABB UNITROL / AC800M / Bailey control systems
  • Standard form-factor “Bailey card” style, suitable for rack / backplane insertion
  • Listed with one-year warranty in aftermarket listings
UNS0867 A-P V2
UNS0867 A-P V2
UNS0867 A-P V2
UNS0867 A-P V2

Applications & Industry Context

In many power plants, turbine generator systems, or legacy utility control systems, the UNITROL or Bailey control families are still prevalent. These systems often require modular expansion of I/O (input/output) capacity to meet evolving monitoring or control needs. The ABB UNS0867 A-P V2 is an extension module designed to be inserted into such control systems to add analog and digital signal capacity.

Notably, the “V2” version of the UNS0867 is distinguished from its predecessor (V1) by its ability to handle analog I/O—not just digital. In one listing, the UNS0867 A-P V2 is promoted as an “I/O extension card with analog signals,” distinguishing it from the V1 version that is described as “without analog signals.”

Thus, in systems where you want to expand analog acquisition (e.g. voltage, current, sensor analog loops) as well as discrete digital inputs, this module is applicable. Plant engineers often use it to add extra measurement capacity when the base control rack is full or lacks extra analog input modules.

Because many plants still run ABB’s UNITROL or AC800M / Bailey systems, this module fits naturally in that ecosystem. Many aftermarket sellers list it as a “Bailey card” intended for these legacy or mixed automation platforms.

Having such extension I/O modules helps in retrofit or upgrade scenarios: you might wish to add new sensors or control loops without replacing the entire control system. The UNS0867 A-P V2 offers a modular, drop-in way to expand I/O.

Product Role & System Fit

At the system level, the UNS0867 A-P V2 acts as an extension or daughter card to the main controller or I/O rack, plugging into the UNITROL / Bailey backplane. It acts as an I/O expansion board, offering both analog and digital channel support—for signals such as voltage input, current sensors, discrete status lines, etc.

In terms of system fit:

  • It complements the core UNITROL F control family, as referenced in listings that call it a “UNITROL F I/O extension card.”
  • It seems to belong to the same hardware family where V1 is the digital-only version, and V2 adds analog signal handling.
  • It would be used in a control rack with backplane connectors, inserted alongside CPU, power, and other modules. The control software (Bailey / UNITROL) would treat it as a remote I/O extension.
  • Because it’s loosely marketed as a “voltage measuring unit” in some listings, it is likely that one of its analog roles is the measurement of voltage or similar loops.

From a maintenance or integration perspective, it’s critical to ensure that firmware, configuration, and backplane wiring match what the main system expects—especially when switching from digital-only to mixed analog/digital modules.

Technical Features & Benefits

Given limited official specification data, here is a summary of likely features based on listings and functional inferences, plus the benefits in practice:

Analog + Digital Capability (versus V1 which is digital only)
The V2 version is often described as “I/O extension card with analog signals,” indicating it supports analog measurement channels in addition to digital ones.
Benefit: Enables new analog sensor integration without needing a complete system redesign.

Voltage Measuring Unit Role
One listing calls it a “voltage measuring unit” (“ABB UNS0867 A-P V2 Voltage Measuring Unit”)
Benefit: May provide built-in circuitry for measuring system/bus voltage or similar, reducing the need for separate voltage input modules.

Bailey / UNITROL Compatibility
Listed by some shops as a “Bailey card” for ABB systems.
Benefit: Easier integration into existing ABB legacy control systems, less risk of incompatibility.

Standard Module Format / Backplane Plug-in Design
Described as “extension card” consistently in listings.
Benefit: Easy to install / swap, minimal wiring disruption, compact upgrade path.

Warranty / Aftermarket Stock
Many listings mention availability of new units with a “one year warranty.”
Benefit: Confidence in spares programs, manageable lifecycle risk.

In practice, I/O extension modules are one of the most common points of upgrade or failure in aging control systems. Having a V2 version that adds analog capacity is especially valuable in retrofit scenarios. Swapping a module usually restores I/O functionality quickly when a channel fails or when new loops are required.

Technical Specifications Table (Estimated / Inferred)

Specification Detail / Value (based on listings / inference)
Model UNS0867 A-P V2
Series / Family UNITROL F / Bailey / I/O Extension
Function I/O Extension Module (mixed analog + digital)
Analog Signals Supported Yes (added in V2 vs V1)
Digital Signals / Channels Likely digital inputs/outputs (exact count not public)
Measuring Role Voltage measuring capability in some listings
Warranty 1 year (supplier listing)
Compatibility / System ABB UNITROL / Bailey / AC800M control systems
Module Format Plug-in / backplane card “extension card” style
Differentiation from V1 V1 lacks analog capabilities, V2 supports analog

Because precise channel counts, voltage ranges, isolation ratings or environmental ratings are not publicly documented in the sources I found, those should be sourced and confirmed from ABB internal datasheets.

Related Models

  • UNS0867 A-P V1 – digital-only extension card (no analog support)
  • Other UNITROL / Bailey I/O / extension modules in the UNS, UA, UB series
  • Analog I/O, digital I/O, power supply boards used in the same control rack ecosystem

Knowing which variant (V1 vs V2) is used in your system is critical—mixing modules can lead to configuration mismatches or error conditions.

Installation & Maintenance Insights

From practical engineering experience with control system modules, here are tips for installing or maintaining UNS0867 A-P V2:

  • Check System Compatibility First: Confirm your control rack supports V2 modules and that firmware, addressing or mapping is configured to expect analog I/O.
  • Power and Backplane Isolation: When inserting or removing I/O cards, power down the backplane or isolate supply to avoid bus faults.
  • Match or Migrate Configuration: If replacing V1 with V2, you may need to migrate configuration settings or reassign analog channel mappings in the control software.
  • Verify Signal Wiring: For analog loops, ensure proper shielding, grounding, and signal integrity (e.g. 4–20 mA wiring). Miswiring is a common source of analog I/O errors.
  • Test Channels After Installation: Run diagnostics to verify analog and digital channels read correctly, and check the voltage measurement function (if applicable).
  • Spare Strategy: Keep at least one spare UNS0867 A-P V2 (or V1, as applicable) configured for your system in your inventory. Because modules are plug-in, swapping is faster than diagnosing wiring.
  • Record Module Details: Serial number, revision (V2), slot position, configuration mapping, software version—record these for future reference.
  • Periodic Maintenance: Inspect for corrosion, connector degradation, dust ingress; re-tighten connections; confirm signal integrity at routine intervals.

By following these practices, you maximize module uptime and reduce diagnostic cycles when channels fail or new loops need adding.