Description
In the rugged expanse of industrial automation, where robust protection against short circuits, overloads, and arc faults is essential to safeguarding sensitive control circuits, power distribution panels, and field wiring from catastrophic failures that could trigger emergency shutdowns or equipment damage, electrical engineers often grapple with the trade-offs of bulky breakers that consume valuable DIN-rail space or lack the granularity for precise trip curves in variable-load environments. These issues intensify in distributed setups like manufacturing control cabinets or renewable energy inverters, where a delayed response to a 200% overload might escalate to ground faults or thermal runaway, compromising signal reliability and process control while inflating downtime costs under standards like IEC 60947-2. The ABB UNC4673A emerges as a compact, high-performance miniature circuit breaker tailored for ABB’s S800 I/O and low-voltage protection ecosystems, delivering reliable branch circuit safeguarding with adjustable magnetic trip settings and thermal-magnetic actuation to ensure high reliability without the footprint penalty of larger MCCBs. Picture a PLC marshalling panel in a chemical dosing skid: a transient surge from a solenoid could overload a 10 A feeder, risking I/O module burnout, but the ABB UNC4673A—with its C-curve characteristics and 10 kA breaking capacity—trips in under 50 ms, isolating the fault while preserving adjacent loops for seamless recovery in System 800xA. It’s indispensable in modular protection schemes, from retrofitting legacy panels to scaling S800 nodes in humid or dusty enclosures, where its DIN-rail mounting and terminal compatibility support goals like reduced panel density and enhanced process control uptime. This breaker aligns with industrial automation’s safety ethos, embedding auxiliary contacts for remote status polling via Profibus DP while curbing the engineering drag of fused links or oversized protectors. Far from a generic switch, the ABB UNC4673A instills a vigilant barrier, empowering teams to fortify circuits with the precision that turns potential hazards into contained events, in environments where trip tenacity delineates routine safeguards from systemic safeguards.
The ABB UNC4673A functions as a thermal-magnetic miniature circuit breaker in the protection tier of ABB’s S800 I/O and low-voltage distribution architectures, interrupting fault currents up to 10 kA at 230/400 V AC while providing manual on/off control via toggle handle, positioning it as a frontline defender between field devices and backplane power rails. It clips onto 35 mm DIN rails in control enclosures, interfacing through box-lug terminals for 1-2.5 mm² wiring, where it leverages bimetallic strips for overload protection (5-10x In thermal) and electromagnetic coils for instantaneous shorts (5-10x In magnetic), ensuring compliance with UL 489 or IEC 60898 without active electronics. In a standard S800 configuration, it safeguards a 16 A feed to AI810 analog inputs, integrating auxiliary contacts (1NO/1NC) for connection to DO810 outputs or CI801 fieldbus nodes, relaying trip states over Modbus RTU for SOE logging in AC 800M controllers. This setup supports redundancy through paralleled branches, where a secondary ABB UNC4673A backs primaries for selective coordination in hot-standby loops, preventing nuisance trips from cascading. Diagnostics rely on visual handle positions and optional shunt trips for remote resets, while its arc chutes minimize let-through energy to protect downstream I/O from damage. Nestled at the power entry of the I/O stack, it decouples fault energies—like inrush from contactors—from logic tiers, ensuring clean propagation for sequencing or alarming in rack ecosystems. For hybrid expansions, the ABB UNC4673A pairs with ABB’s System pro M auxiliaries, anchoring evolutions from standalone feeders to fault-resilient DCS meshes where branch fortitude underpins seamless process control.
- UNC4673A
- UNC4673A
| Specification | Details |
|---|---|
| Model Number | UNC4673A |
| Brand | ABB |
| Type | Miniature Circuit Breaker |
| Input Voltage | 230/400 V AC |
| Operating Temp Range | -25°C to +75°C |
| Mounting Style | DIN Rail (35 mm) |
| Dimensions | 85 mm x 18 mm x 80 mm (per pole) |
| Weight | 0.1 kg |
| Interface/Bus | N/A (Terminal-based) |
| Compliance | CE, UL 489, IEC 60898 |
| Supported Protocols | N/A |
| Typical Power Draw | 0 W (Passive) |
Opting for the ABB UNC4673A equips your distribution with a breaker built for unyielding interception, where its C-curve selectivity and 10 kA Icu thwart the overloads that plague unprotected rails, yielding circuits that sustain 100% loads through transients and fewer arc-flash incidents that preserve compliance in hot-run bays without the sprawl of MCCBs bloating panel audits. In the rhythm of field exposures, this reliability manifests as handles that hold positions through vibrations, letting crews dial in protections like magnetic thresholds on flux feeds rather than flux firefighting post-fault.
The breaker’s DIN-slender shell and terminal versatility further par assimilation burrs, as snap-fit mounting hastens cabinet proofs, compressing FAT windows and funneling acumen to layered safeties over lug hunts in legacy ties. Upkeep acquires a leaner line too, with visual flags and aux contacts that cue trips upfront—thru bus pings—narrowing probes to selective resets and widening spans betwixt blanket retests, compounding to a slimmer spares cache and amplified asset arc.
At its crux, the ABB UNC4673A curates a vigilant vein in branch-burdened industrial automation, where such sentinels not only gird interruption integrity but also kindle corridors for woven wards, like adaptive aux on flux fluxes, all unyoked by the coil of cascaded fuses or the gulfs of unchecked quivers.
In solar inverter cabinets, the ABB UNC4673A guards DC-AC feeders from string surges, where it clinches high reliability amid flux fluxes and thermal throbs, bracing process control environments that bank on trip-true polls for harvest handoffs in variable-gen process control webs.
Pharma cleanroom panels harness the ABB UNC4673A for HVAC interlock branches, upholding critical system uptime against sterile streams and filter fluxes, with breaker clout ensuring containment holds tight and nips imbalances in GMP process control scaffolds.
Oil rig motor controls embed the ABB UNC4673A to protect pump starters, backing fast data cycles under saline shakes and load lurches, where its interruption poise holds command streams steady and balks stalls in offshore process control frames.
UNC4672A – B-curve variant for lower inrush applications in sensitive electronics.
UNC4674A – D-curve edition for high-startup loads like motors.
S201-C16 – Supplementary protector companion for finer current grading.
AF contactors – Switching device pairing for motor circuit integrations.
S802PV – High-current MCB add-on for photovoltaic DC protection.
TU811 – Termination unit for S800 I/O ties post-breaker.
SD831 – Power supply module for redundant 24 V feeds upstream.
3BSE008572R1 – Fused MTU variant for analog loop safeguards.
Before deploying the ABB UNC4673A, confirm the C-curve trip band suits your load profile—5-10x In for general circuits—to avoid nuisance interruptions, and verify DIN rail load capacity exceeds 10 breakers without sagging, while torque terminals to 1.2 Nm for 1 mm² wires to prevent hot spots. In humid bays, ensure enclosure IP54 minima to honor the -25°C to +75°C range, and perform a pre-install continuity check with a multimeter to baseline resistance under 0.05 Ω, mapping aux contacts to 800xA for status baselines sans live risks.
Ongoing oversight keeps it straightforward: inspect handle positions monthly during patrols for free movement, and scan for arc marks on poles in dusty sites—clean with dry air if needed. Annually, during shutdowns, execute a full-trip test with a secondary injection kit per IEC 60898, isolating the breaker without panel halts, and lubricate mechanisms lightly to curb friction in hot zones. These habits ensure the ABB UNC4673A remains a silent sentinel, flagging frailties through aux alerts rather than field flares, with minimal meddling to sustain your circuit’s cadence.




WhatsApp: +86 16626708626
Email:
Phone: +86 16626708626