Description
Product Model: TU810V1
Product Brand: ABB
Product Series: S800 I/O – Compact Module Termination Units (MTU)
Product Features:
- 16-channel compact module termination unit (MTU) rated at 50 V for ABB S800 I/O systems.
- Provides field-wiring connection, ModuleBus link, and mechanical keying to prevent wrong I/O module insertion.
- DIN-rail mountable and designed for compact installations with one-wire connections for field signals and process power.
- Ordering P/N: 3BSE013230R1.
- TU810V1 3BSE013230R1
- TU810V1 3BSE013230R1
Technical Features & Benefits
The TU810V1 stands out as a robust and practical termination unit designed to bring together field wiring, I/O modules and the internal ModuleBus in the ABB S800 I/O system. At its core, this compact module termination unit (MTU) handles up to 16 channels of field-signal wiring (as shown in the datasheet: 16 channels, 50 V rating).
One of the key benefits: by bundling field wiring and module terminations into a standardized block, you reduce installation complexity. The TU810V1’s design includes mechanical keying—two key-positions allow 36 possible configurations—ensuring that an improper I/O module cannot be inserted into the wrong slot, thereby reducing wiring or module mismatch errors.
Another advantage is its compactness and DIN-rail mounting suitability. The unit supports horizontal mounting up to 55 °C and vertical mounting up to 40 °C, which means it can fit neatly in control cabinets without sacrificing reliability in typical industrial ambient conditions.
From a performance standpoint, the unit supports a process voltage of 50 V and allows up to 2 A current per I/O channel (as per the technical data). This makes it suitable for many low-voltage field devices, sensors, or auxiliary signals. Using this termination block in the control system ensures that your field wiring, module bus, and signal logic are connected through standardized, manufacturer-specified architecture—lessening chances of mis-wiring or custom non-standard blocks.
Moreover, since the TU810V1 is a passive module (no active electronics), it reduces failure risk—fewer parts to fail—and consequently lowers maintenance burdens compared to active modules. The module also distributes the ModuleBus to I/O modules and onwards to the next MTU, making it a crucial link in the chain of I/O modules in the S800 architecture.
In practical field implementations, replacing an older termination unit with a fresh TU810V1 (or upgrading to this version) often resolves issues related to poor contact, loose wiring, or repeated module-bus faults. Engineers frequently mention that many “mystery” I/O errors turn out to be shared termination blocks or wiring contacts—not the I/O module itself—and using a high-quality termination unit like TU810V1 dramatically improves system reliability.
Product Role & System Fit
In the automation architecture of the ABB S800 I/O system, the TU810V1 functions at the field-interface layer. It sits between the physical field wires (sensors, actuators, switches) and the I/O module (such as AI810, DI830, AO845, DO880 etc.). According to its datasheet, TU810V1 supports use with many of these modules.
Operationally, the termination unit performs several roles: it holds the field-wiring terminations, supports the process power distribution (e.g., 2×2 process power connections and 5×2 process power for 0 V as per datasheet) provides the ModuleBus link to the I/O module and provides key-ing to avoid module mismatch. In effect, the TU810V1 ensures your I/O module is correctly installed and interfaced to the field wiring.
From a systems-engineering perspective, when designing or maintaining a control cabinet, the TU810V1 is part of the backbone that ensures modular deployment and standardized layouts. Because it supports up to 16 channels in a compact form, it helps optimize rack space and wiring. Having consistent termination units simplifies spares, documentation, and panel build out.
This module is particularly beneficial in expansion or retrofit scenarios. If you have an existing ABB S800 system, TU810V1 allows you to mount new I/O modules without redesigning termination layout; it’s compatible with the cable routing and mechanical mounting used in earlier units. The specification of 50 V low-voltage field signals fits many analog/ digital I/O modules for sensors and actuators. It enables field wiring standardization and clearer control-cabinet layouts.
Applications & Industry Context
Across a wide range of industries—such as power generation, oil & gas, chemical processing, water/wastewater treatment, manufacturing lines—the reliability and clarity of I/O wiring and termination are vital. The TU810V1 is especially appropriate where modularity, reliability, and serviceability matter.
Consider a large petrochemical plant with multiple distributed I/O racks installed for process control. Each I/O rack might host dozens of I/O modules (analog inputs, digital outputs, etc.). The TU810V1 provides the termination and standard interface, enabling engineers to more easily maintain, test and replace I/O modules. When a field device fails or a wiring contact becomes unreliable, the termination unit is often the first point of inspection—having a high-quality termination unit like TU810V1 means fewer field failures.
In water/wastewater treatment installations, where environmental factors (moisture, dust, temperature swings) challenge electronics, the robust mechanical mounting and key-ing intelligence of TU810V1 help maintain reliability. The mechanical keying also prevents incorrect module insertion during field service—very useful when less experienced technicians perform module swaps.
In manufacturing plants with high uptime demands, having standard termination modules across multiple racks (TU810V1), with consistent wiring practices, helps reduce mean time to repair (MTTR). When a failure occurs, field wiring diagnostics become easier thanks to good term blocks, proper labeling and modular architecture.
For retrofit installations of ABB’s S800 I/O systems, the TU810V1 is often chosen as the drop-in termination unit when modernizing or expanding existing racks. Because it supports the same module bus and mechanical mounting as previous versions but with updated keying and clearer specification, using TU810V1 simplifies planning and spares stocking.
Technical Specifications Table
| Specification | Detail / Value |
|---|---|
| Product Model | TU810V1 |
| Ordering / Part Number | 3BSE013230R1 |
| Product Type | Compact Module Termination Unit (MTU) for ABB S800 I/O |
| Channels | 16 |
| Rated Voltage (Field / I/O) | 50 V |
| Process Connections | 2×2 process power and 5×2 process power (0 V) |
| Max Current per I/O Channel | ~2 A (per datasheet) |
| Mounting Method | DIN-rail, horizontal mounting up to 55 °C / vertical up to 40 °C |
| Mechanical Keying | Two mechanical keys, six positions each (36 configurations) |
| Compatible I/O Modules | AI810, AI815, AI820, AI830/A, AI835/A, AI845; AO810, AO810V2, AO815, AO820, AO845/A; DI810, DI811, DI814, DI830, DI831, DI840, DI880, DI885; DO810, DO814, DO815, DO840, DO880; DP820, DP840. |
| Product Weight | Approximately 0.32 kg net weight |
| Country of Origin | Bulgaria (BG) |
Related Models
Here are some related termination units and modules you may want to compare:
- TU811V1 (3BSE013231R1) – the 250 V version of the Compact MTU, 8 channels.
- TU830V1 (3BSE013234R1) – Extended MTU variant in the S800 family.
- AI810, DI830, DO840 modules – typical I/O modules that mount on MTUs such as TU810V1.
- S800 I/O Modules Termination Blocks – other MTUs for higher voltage or special isolation.
- Spare Terminator Blocks – when planning spares, the TU810V1 provides a standardized baseline termination unit for many I/O modules.
Installation & Maintenance Insights
From hands-on experience as an automation engineer, here are some practical tips when installing or maintaining the TU810V1:
- Cable and Wiring Inspection: Ensure all field wiring is correctly routed and terminated in the TU810V1 block. Poor wiring or loose connections are common sources of intermittent I/O faults. Use proper stripping length (as per datasheet) and check torque on terminals.
- Module Keying Verification: Before inserting an I/O module into the MTU, verify the mechanical key positions. The TU810V1 supports 36 configurations via its keying system, reducing risk of installing an incompatible module. Ensuring correct keying prevents module bus or channel faults.
- DIN-Rail Grounding and Mounting Orientation: Mount the TU810V1 on a clean DIN rail. Ensure it latches properly and that the rail is properly grounded. Also check ambient conditions: if mounted vertically, keep within 40 °C operational limit; horizontal mounting allows up to 55 °C.
- Segment and Addressing: The TU810V1 passes ModuleBus signals to downstream modules. Ensure that the bus continuity and termination are correct. If you get module-bus faults, inspect the MTU connectors and adjacent wiring rather than immediately blaming the I/O module.
- Spare Strategy and Stocking: Since TU810V1 is widely used in S800 I/O installations, keep at least one spare in stock. Because it’s passive, you avoid the need for firmware updates or configuration—swap out is straightforward.
- Cleaning and Environmental Maintenance: During scheduled maintenance, inspect MTUs for dust accumulation, corrosion on connectors, or signs of overheating. Clean loosen “one-wire” connections if applicable, and ensure the rail is not overloaded.
- Retrofitting Advice: If upgrading an older S800 system, retaining TU810V1 across your rack means you can use new I/O modules without changing the termination block layout. This saves time and helps standardize spares across different racks.
- Replacement Tips: If you replace a TU810V1, note the channel count (16). When unplugging an I/O module, label the module and channel mapping. After installation, perform I/O channel diagnostics from the controller or logic layer to verify each channel is operating.






WhatsApp: +86 16626708626
Email: