The 8810-HI-TX is a high-performance industrial Ethernet transceiver, engineered to facilitate fast and secure data transmission in industrial control systems. It is part of a family of networking components designed to integrate seamlessly into distributed control systems (DCS), supervisory control and data acquisition (SCADA) systems, and industrial Internet of Things (IIoT) networks.
Model 8810-HI-TX
Brand Emerson
Type Industrial Ethernet Transceiver
Power Supply 24V DC
Operating Temperature -40°C to +75°C
Mounting DIN rail (35mm)
Dimensions 100mm x 75mm x 50mm (W x H x D)
Weight 250 grams
Interfaces 1 x RJ45 (copper), 1 x SC/LC (fiber optic)
Data Transfer Rate Up to 10 Gbps
Certifications UL, CE, ATEX, IECEx
Cooling Natural convection
Environmental Rating IP30
The 8810-HI-TX is a high-performance industrial Ethernet transceiver, engineered to facilitate fast and secure data transmission in industrial control systems. It is part of a family of networking components designed to integrate seamlessly into distributed control systems (DCS), supervisory control and data acquisition (SCADA) systems, and industrial Internet of Things (IIoT) networks.
8810-HI-TX
This transceiver acts as a critical bridge between different segments of an industrial network, converting electrical signals to optical signals and vice versa to enable long-distance data transmission. What makes the 8810-HI-TXvaluable for engineers and integrators is its ability to support high data transfer rates while maintaining robustness in harsh industrial conditions. It fits into network architectures by extending the reach of Ethernet networks beyond the limitations of copper cables, allowing for connections between distant plant areas without signal degradation. Its compatibility with standard Ethernet protocols ensures easy integration with existing network infrastructure.
8810-HI-TX
The 8810-HI-TX boasts impressive technical capabilities that set it apart in industrial networking. It supports data transfer rates of up to 10 Gbps, making it ideal for applications requiring high bandwidth, such as video surveillance of production lines or real-time analytics of large datasets. This high speed ensures that even the most data-intensive operations, like synchronous machine control, can be supported without latency issues.
In terms of hardware design, the 8810-HI-TX features a rugged, IP30-rated enclosure that protects against dust and mechanical stress, ensuring reliable operation in industrial environments with high vibration or temperature fluctuations. It incorporates advanced surge protection, withstanding voltage spikes up to 2 kV, which is crucial in areas prone to electrical interference. The transceiver also offers hot-swappable functionality, allowing for replacement without shutting down the entire network—minimizing downtime during maintenance. Its compatibility with both single-mode and multi-mode fiber optic cables adds to its versatility, enabling flexible network design based on distance requirements.
8810-HI-TX
Technical specifications:
Model 8810-HI-TX
Brand Emerson
Type Industrial Ethernet Transceiver
Power Supply 24V DC
Operating Temperature -40°C to +75°C
Mounting DIN rail (35mm)
Dimensions 100mm x 75mm x 50mm (W x H x D)
Weight 250 grams
Interfaces 1 x RJ45 (copper), 1 x SC/LC (fiber optic)
Data Transfer Rate Up to 10 Gbps
Certifications UL, CE, ATEX, IECEx
Cooling Natural convection
Environmental Rating IP30
Contact Us Phone:+86 16626708626 WeChat/WhatsApp:+86 16626708626 Email: 3772179818@qq.com
8810-HI-TX
Application areas:
In the complex networks of industrial automation, where real-time data transmission is the lifeblood of efficient operations, the 8810-HI-TX plays a pivotal role. Take, for example, large-scale manufacturing plants with sprawling production floors, where hundreds of sensors and actuators generate a constant stream of data. This data needs to be transmitted quickly and reliably to central control systems to enable timely decision-making. The 8810-HI-TX is widely used in such environments, ensuring that critical information—from machine performance metrics to safety alerts—flows seamlessly across the network.
In the energy sector, power generation facilities rely on the 8810-HI-TX to transmit data from remote monitoring points, such as turbine sensors and transformer stations, to the main control room. In these settings, even a brief delay in data transmission can lead to inefficiencies or, in worst-case scenarios, equipment damage. The 8810-HI-TX is designed to handle the high data volumes and strict latency requirements of these applications, making it an essential component in ensuring the reliable operation of power plants. Used in industrial automation across manufacturing, energy, and water treatment sectors, it addresses the challenges of long-distance, high-speed data transmission in harsh industrial environments.
8810-HI-TX
Related products:
8810-LO-TX – A lower-speed variant of the 8810-HI-TX, suitable for applications with moderate data transfer needs.
8810-HI-RX – The receiving counterpart to the 8810-HI-TX, designed for paired use in point-to-point connections.
8820-HI-TX – A redundant version of the 8810-HI-TX with dual power inputs, ideal for mission-critical networks.
8700-SW-NA – An industrial Ethernet switch that works with the 8810-HI-TX to manage network traffic in large-scale installations.
8900-MOD-NA – A network monitoring module that integrates with the 8810-HI-TX to provide real-time performance analytics.
8500-CAB-FO – A fiber optic cable assembly optimized for use with the 8810-HI-TX in long-distance connections.
8400-PWR-NA – A power distribution unit that supplies stable power to multiple 8810-HI-TX transceivers in a network rack.
Installation and maintenance:
Before installing the 8810-HI-TX, ensure that the mounting location provides adequate ventilation to prevent overheating, especially in enclosures with multiple networking components. The transceiver should be positioned away from sources of electromagnetic interference, such as large motors or variable frequency drives, to avoid signal disruption. When connecting fiber optic cables, use proper cleaning tools to remove dust from connectors—even small particles can cause signal loss. Verify that the fiber cable type (single-mode or multi-mode) matches the transceiver’s specifications to ensure optimal performance.
For maintenance, conduct visual inspections of the 8810-HI-TX every three months to check for loose connections or damage to the enclosure. Monitor network performance metrics, such as packet loss and latency, using network management software to identify potential issues early. Clean fiber optic connectors annually with specialized cleaning kits to maintain signal integrity. Firmware updates should be applied during scheduled maintenance windows, using the manufacturer’s secure update tool to ensure compatibility with network protocols. Avoid hot-swapping during peak production hours to prevent temporary network disruptions.